MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
Remember to vacuum the combustion chamber before each ignition
Should ignition fail, do not re-ignite until you have emptied the combustion chamber
Attention: the pellet emptied from the combustion chamber mustnotbe deposited inside the hopper.
Regular maintenance is required for the boiler- replace to function correctly.
The boiler- replace will trigger the message: 'smoke °C/high' or 'Mainten.' to appear on the panel when further cleaning
is necessary. This is preceded by 'Clean exchang.' appearing on the display.
Failure to perform regular maintenance, at least on a seasonal basis, could lead to poor functionality.
Any problems resulting from lack of maintenance will immediately void the warranty.
NOTE: The DEALER, upon commissioning, sets the kg value of consumed pellets; after which, the message "SERVICE
UTE" will appear on the display. The boiler- replace continues operation, but the end client is invited to perform careful
maintenance, described above and explained by the DEALER during commissioning, to the extent of his abilities. To elimi-
nate the message from the display, press the boiler button for at least 5 seconds after having completed maintenance.

DAILY MAINTENANCE

Operations must be performed when the boiler- replace is off, cold and unplugged from the power supply
• Must be performed using a vacuum cleaner (see optional extras page 43), the whole procedure takes up a few minutes every day.
• Open the door, remove the combustion chamber (1 - g. A) and empty the residue out into the ash pan.
• Scrap the combustion chamber with the spatula provided, removing any obstructions in the openings.
• IN NESSUN CASO SCARICARE I RESIDUI NEL SERBATOIO DEL PELLET.
• Take out and empty the ash (2 - g B) pan into a reproof container (the ash may still contain hot parts and/or embers).
• Remove the combustion chamber or use the spatula to scrape it and clean out any blocked holes on all sides
• Vacuum the combustion chamber holder, clean the edges where the combustion chamber is lodged into its seat.
• Clean the glass, if necessary (when cold).
NEVER SUCTION HOT ASH, as this could damage the suction device and possibly cause a re.
1
2
g. A
g. B
WEEKLY MAINTENANCE
(picture on following page)
• Clean the hearth after having removed the ash pan (2 - g. C) and the smokebox plate (3 - g. C).
• Suction clean the smokebox compartment (4 - g. C)
• Clean the chimney ue using the swabs moving the relative metal levers up and down (6 - g. D).
• Clean the combustion chamber and the smoke extractor, paying careful attention (5 - g. C).
• To clean the chimney ue, proceed as follows:
Open the external door and the lower panel; remove the 3 screws to open the chimney ue's inspection hole and (7- g. E) and
suction the residue. The quantity of residue that forms depends on the type of fuel used and the type of system.
Note:
1) Be sure to close the inspection hole once this operation is complete.
2) Failure to clean the chimney ue will cause boiler- replace stoppage.