Download Inhoudsopgave Inhoud Print deze pagina

Through Glass Windows; Next To Walls Containing Electrical Wiring; Use; Adding Optional Wireleess Components - Indexa EW01 Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 13
#
Avoid metal doors, cupboards and similar objects in the detection area
(see Fig. D, I and III).
#
Ensure that there are no heat sources, microwave ovens or wireless
surveillance cameras within the detection area, these can cause false
triggering.
#
Place the main unit inside the property with the back side towards the
wall on the other side of which the movement is to be detected, eg. next
to the front door or patio door.
#
Place the main unit, if possible on a table or shelf directly against the
wall (see Fig. D, II and IV).
#
You can also hang the unit on the wall at a height approx. 0.8 - 1.5m
from the floor:
!
Drill two suitable holes with a horizontal separation of 5 cm.
Note:
Test the function and the detection area from the proposed
location before drilling the holes.
!
If required, place the supplied wall plugs [22] into the holes.
!
Secure the supplied screws [23] so that the screw heads protrude
5 mm out of the wall.
!
Hang the main unit on the wall so that the hanging slots [7] are
located over the screw heads.
Do not place:
#
Through walls f caravans
The microwave sensor does not detect through the aluminium coated
walls. Can be used behind curtains directly through plastic windows.
#

Through glass windows

The microwave sensor does not detect through coated or wired glass or
double glazing
#

Next to walls containing electrical wiring

Electrical fields can cause permanent triggering

9. Use

!
Push the switch [9] to the required position:
B
ark mode
C
hime mode
S
iren mode (upper or lower position, there is no difference)
!
Turn the range adjuster [3] to the position "MAX".
!
Turn the volume adjuster [4] to the required volume. The power LED [6]
lights (colour: see chapter 11) and the unit is now in stand by mode.
!
To arm the unit, press the I/O button [10] or [17]. The armed mode will
be indicated by illumination of the arm LED [5] and audiably by:
B
ark mode
1x bark
C
hime mode
2x "ding-dong"
S
iren mode
3 peeps
A
fter a warm up period of approx. 60 sec. the readiness of the detector is
signalled by one peep.
I
f motion is detected the unit reacts according to the set mode:
B
ark mode
1
detection within 5 sec.
2
detections within 5 sec.
3
or more detections within 5 sec.
GB - 20
1 bark
3X bark
10 sec. Bark
C
hime mode
d
etection
S
iren mode
1
detection within 5 sec.
2
or more detections within 5 sec.
!
The detection range of the sensor can be adjusted using the range
adjuster [3]. Set this at the minimum level required for the desired
detection. At the maximim range setting the unit sensor is very sensitive
and may react to other disturbances.
!
Use the adjuster [4] to set the desired volume.
!
To disarm the unit and to cancel the reaction to movement press the
buttons [10] or [16]. The LED [5] is no longer illuminated.
!
To manually activate a siren sound for approx. 20 sec. Press the panic
button [18] on the remote control. This function can be activated when
the unit is in armed or disarmed mode. If the unit was in the armed
mode it will remain armed after the 20 sec. siren.
!
To cancel the siren sound within 20 sec. Press the button [10] or [16]. If
the unit was armed, it will now be disarmed.
!
To turn off the unit turn the button [4] to the position "OFF" (a click
sound can be heard). After a short pause, the power LED [6] is no longer
illuminated.
!
To turn on the unit into standby mode turn the button [4] clockwise to
the required volume setting.
1
0. Adding optional wireless components
D
eleting all the wireless components
T
he following optional components can be enrolled into the main unit:
#
Additional remote control EW01R (max. 1x) (Art.-No. 33557) / MA80R
a
nd up to a total 6x of the following detectors:
#
Wireless door/window contact MA80KM (Art.-No. 33552)
#
Wireless PIR-movement detector (indoor) MA 80 P (Art.-No. 33551)
E
ach wireless component has a unique coding set in the factory. This code
must be enrolled into the main unit:
!
Install the batteries into the wireless component. Ensure that the main
unit is not armed, the LED [5] is not illuminated.
!
Depress the LEARN button [8] until a peep sound can be heard. The unit
is now in the learning mode for 20 sec. (LED [5] flashes).
!
Move within the detection area of the MA80P, or separate the magnet
away from the reed switch of the MA80KM, or press a button on the
EW01R / MA80R. A coded signal will be transmitted to the main unit.
!
Two long peep sounds will confirm the successful enrollment of the code
of the component into the main unit.
!
If within 20 sec. no component has been enrolled the learning mode will
be automatically cancelled. This is signalled by 4 peep sounds.
!
Repeat the above steps for each component. If a component is enrolled
for a second time the first enrollment is automatically cancelled.
I
f a wireless detector is activated (from MA80KM door or window opened,
movement detected by MA80P) when the main unit is armed, then the unit
reacts depending on the mode setting as follows:
2x "ding-dong"
3 sec. Siren
20 sec. Siren
/