ASCO™ 273 AND 373 SERIES
PNEUMATIC PINCH VALVE
TUBES COMPATIBILITY TABLE AT 25°C (77°F)
tube I.D.
tube O.D.
tubing type
Watson Marlow
P273A-32-----00
6.4 (1/4)
3.2 (1/8)
913.AI32.016
AdvantaFlex
APAF-BP
C-Flex
®
374
Pharma 80
9.5 (3/8)
Saint Gobain
AND00017
6.4 (1/4)
AN800017
P273A-12-----00
ACF00017
Watson Marlow
913.A064.016
9.6 (3/8)
941.0064.016
Saint Gobain
6 (1/4)
9 (3/8)
ABX6FB020-C
®
C-Flex
374
TYGON
B-44-4X
®
12.7 (1/2)
Pharma 80
Vena
®
,
6.4 (1/4)
P273A-14-----00
TECHNOSIL
P373A-14-----00
Watson Marlow
12.8 (1/2)
913.A064.032
12.4 (1/2)
BPSHP0250-C BioPure Silicone single braided hose (7,6)
Saint Gobain
6 (1/4)
12 (1/2)
ABX6FB022-C
TYGON
B-44-4X
®
P273A-13-----00
9.5 (3/8) 12.7 (1/2)
Pharma 80
AdvantaFlex
APAF-BP
C-Flex
®
374
P273A-15-----00 12.7 (1/2) 19.1 (3/4)
TYGON
B-44-4X
®
Pharma 65
Pharma 80
In accordance with the manufacturer's specifications, a single cycle of gamma radiation up to 40 kGy has minimum
(1)
effect on mechanical properties of the tubing. No effect has been observed on valve's performances when used with an
irradiated sample of tubing."
Maximum media pressure for reference only. It is user's responsibility to verify performance. Please contact tubing
(2)
manufacturers for maximum working pressure and temperature.
The tubing has been tested with air at the maximum pressure stated in the table above. After 20000 pinching cycles in the
same spot of the tubing, no fully-penetrated surface cuts or compromised integrity have been observed in our testing.
Please contact ASCO to verify suitability for any condition not stated in the above table.
®
AdvantaFlex
is a registered trademark of NewAge
and TYGON
and TYGOPRENE
and VERSILON™ are registered trademarks of Saint-Gobain Performance Plastics.
C-Flex
®
®
®
PUMPSIL
and PUREWELD
are registered trademarks of Watson & Marlow NewAge
®
®
Vena
®
is a registered trademark of Venair.
Visit our website at Emerson.com/ASCO
tubing nominal
tubing material
hardness
(Shore A)
Platinum-cured silicone tubing
60
(PUMPSIL
®
)
®
,
TPE
65
TPE
60
80
Platinum-Cured Silicone
TYGON
®
E-65-F
65
TYGOPRENE
XL-60
®
60
TYGON
®
E-3603
56
Platinum-cured silicone tubing
60
(PUMPSIL
®
)
Weldable biopharmaceutical tubing
65-73
(PUREWELD
XL)
®
VERSILON™ SPX60-FB
61
TPE
60
PVC
66
80
Platinum-Cured Silicone
Braided Silicone
70/60
Platinum-cured silicone tubing (Pumpsil)
60
-
VERSILON™ SPX60-FB
61
PVC
66
80
Platinum-Cured Silicone
®
,
TPE
65
TPE
60
PVC
66
Platinum-Cured Silicone
65
80
Platinum-Cured Silicone
®
Industries, Inc.
®
Industries, Inc.
26
max. tested
media pressure
(2)
bar (psi)
2.0 (29)
0.8 (12)
12.7 (1/2)
1.0 (15)
P273A-15-----00
4.0 (60)
(1)
0.9 (13)
1.0 (15)
12.7 (1/2) 20,3 (3/4) BPSHP0375-C BioPure Silicone single braided hose (7,6)
1.4 (20)
P273A-16-C---00 19.1 (3/4) 25.4
2.0 (29)
2.0 (29)
0.38 (5.5)
P273A-16-P---00 19.1 (3/4) 25.4
1.0 (15)
2.1 (30)
4.0 (60)
(1)
6.0 (90)
2.0 (29)
4.0 (60)
0.65 (29)
1.7 (25)
4.0 (60)
(1)
0.8 (12)
1.0 (15)
1.4 (20)
4.0 (60)
(1)
4.0 (60)
(1)
(1)
In accordance with the manufacturer's specifications, a single cycle of gamma radiation up to 40 kGy has minimum
effect on mechanical properties of the tubing. No effect has been observed on valve's performances when used with an
irradiated sample of tubing."
Maximum media pressure for reference only. It is user's responsibility to verify performance. Please contact tubing
(2)
manufacturers for maximum working pressure and temperature.
The tubing has been tested with air at the maximum pressure stated in the table above. After 20000 pinching cycles in the
same spot of the tubing, no fully-penetrated surface cuts or compromised integrity have been observed in our testing.
Please contact ASCO to verify suitability for any condition not stated in the above table.
AdvantaFlex
®
is a registered trademark of NewAge
and TYGON
C-Flex
®
PUMPSIL
and PUREWELD
®
ASCO™ 273 SERIES
PNEUMATIC PINCH VALVE
TUBES COMPATIBILITY TABLE AT 25°C (77°F)
tube I.D.
tube O.D.
tubing type
Saint Gobain
19.8 (3/4)
ACF00038
TYGON
19.1 (3/4)
AN800038
TYGOPRENE
Watson Marlow
913.A127.032
Platinum-cured silicone tubing
19.1 (3/4)
941.0127.032
Weldable biopharmaceutical tubing
(PUREWELD
9.6 (1/2) 16.7 (3/4) BPSHP0375-C BioPure Silicone single braided hose (7,6)
AdvantaFlex
®
,
APAF-BP
(1)
®
C-Flex
374
Pharma 50
Platinum-Cured Silicone
®
AdvantaFlex
,
APAF-BP
C-Flex
®
374
(1)
TYGON
B-44-4X
®
Pharma 50
Platinum-Cured Silicone
Pharma 80
Platinum-Cured Silicone
®
Industries, Inc.
and TYGOPRENE
are registered trademarks of Saint-Gobain Performance Plastics.
®
®
are registered trademarks of Watson & Marlow NewAge
®
27
Visit our website at Emerson.com/ASCO
tubing nominal
max. tested
tubing material
hardness
media pressure
(Shore A)
bar (psi)
1.4 (20)
®
E-3603
56
XL-60
1.0 (15)
®
60
2.0 (29)
60
(PUMPSIL
®
)
2.0 (29)
65-73
XL)
®
4.0 (60)
-
4.0 (60)
-
0.8 (12)
TPE
65
1.0 (15)
TPE
60
1.6 (25)
(1)
50
0.8 (12)
TPE
65
1.0 (15)
TPE
60
1.4 (20)
PVC
66
1.6 (25)
(1)
50
80
4.0 (60)
(1)
®
Industries, Inc.