5.3 User modes
This device can be used in the exhaust or recirculation mode
(standard setting upon delivery)
5.3.1 Exhaust mode
The air sucked in is first cleaned by the grease filters before
being removed to the outside. This can be achieved by making
use of a series of channels connected between the device and
a wall exhaust cover.
To set the device in exhaust mode, press and hold the key
+
‐
combination
and
and
extraction tower is closed.
The led next to the Cleaning indication for recirculation filter will
blink 3x.
5.3.2 Recirculation mode
The air sucked in is first cleaned by the grease filters. The scents
are then removed in the recirculation filter before re-entering the
kitchen.
To set the device in recirculation mode (default setting), press
and hold the key combination
when the extraction tower is closed.
The led next to the Cleaning indication for recirculation filter will
be on for 3 seconds.
INFO: Provide adequate ventilation in the kitchen
for optimal efficiency of the recirculation system.
for 3 seconds when the
+
‐
and
and
for 3 seconds
5.4 Controlling the extraction tower
WARNING: When the extraction is activated,
the extraction tower automatically rises to
the desired height at the rear of the induction
hob. Therefore, ensure nothing can hinder its
movement.
Switch on 10 cm
Briefly press
Switch on 30 cm
Press and hold
Switch AUTO on 20 cm
Press
Switch on run-out function
Press and hold
Switch off
Briefly press
Other positions of the extraction tower: The extraction tower
can be set in 3 different standard positions: 10, 20 and 30 cm
via the
and
If you wish to choose an intermediate height yourself, you can
stop the suction tower at any position while the extraction tower
is moving.
Press the
button if the extraction tower moves upwards,
or
if it moves downwards.
AUTO function: Preset function where the extraction tower
immediately comes into position at the most common cooking
height of 20 cm. The extraction mode 5 (3rd led) is automatically
set.
Run-out function: This function starts at the end of cooking.
For a fixed time, the remaining cooking vapours will be extracted
from the kitchen by the extraction tower at low extraction mode
and at a height of 10 cm. When recirculation is selected, the
recirculation filters are also dried.
The run-out time is set to 30 minutes by default in the recirculation
mode and 10 minutes in exhaust mode. It is recommended that
this function be allowed to carry out its function completely. At
the end of the run-out time, the motor and the extraction tower
will automatically switch off and the tower will close.
– 58 –
Extraction tower:
for 2 seconds
for 2 seconds
buttons.
Display
LED
lights up
LED
lights up
LED
lights up
LED
blinks
LED
off