7. Complete the installation of the appliance and fix the oven with 4 screws (fig. 2, right
side).

2.4 Electrical connection

Instructions for the installer (qualified professional)
❖ The cooker is manufactured to work with three-phase alternating current
(400V3N~50Hz). Remember that the connection wire should match the connection
type and the power rating of the cooker. The connection cable must be secured in a
strain-relief clamp. The ground wire must be connected to the marked clamp of the
terminal. The electric supply of the appliance must be equipped with an emergency
switch with a distance between the contacts of at least 3 mm which disconnects the
entire appliance from the mains in a case of emergency. Read the information on the
rating label and the connection diagram before connecting the appliance to the
mains.
❖ When the socket is not accessible for the user or a fixed electrical connection of
the appliance is required, an all-pole disconnecting device must be incorporated
during installation. Disconnecting devices are switches with a contact opening
distance of at least 3 mm. These include LS-switches, fuses and protectors (EN
30335).