Adjust the internal setting screw until a stable flame is
4.
burning correctly.
Loosen the adjuster screw to increase the gas flow or tighten
it to decrease the gas flow.
Check that the flame does not go out when the gas flow is
quickly changed between maximum and minimum, and vice
versa.
The setting is correct when the height of the small flame is
approx. 3 to 4 mm.
General nozzle table
Type of
mbar
kPa
gas
Natural
20
2.0
gas - NG
G20
Liquefied
28 -
2.8 -
gas - LPG
30/37
3.0/
Butane
3.7
Propane
G30/G31
General nozzle table for town gas
The nozzles for town gas are not supplied with the appliance.
You can order the nozzles from the after-sales service.
Type of gas
mbar
kPa
Town gas
8
0.8
G110
Town gas
8
0.8
G120
Nominal operating pressure
The nominal operating pressure of your appliance is:
for natural gas - NG (G20) 20 mbar / 2.0 kPa.
for liquefied gas - LPG (G30) 30 mbar / 3.0 kPa.
for liquefied gas - LPG (G31) 37 mbar / 3.7 kPa.
Nominal operating pressure for town gas
The nominal operating pressure of your appliance is:
for town gas (G110) 8 mbar / 0.8 kPa;
for town gas (G120) 8 mbar / 0.8 kPa;
Nozzle
Type of burner Power
Number
Bypass
115 (Y)
Gap
High output
burner
97 (Z)
Gap
Standard burner 1800
72 (X)
Gap
Economy
burner
135 (S)
Gap
Wok burner
85
0.45
High output
burner
65
0.33
Standard burner 1800
50
0.30
Economy
burner
100
0.63
Wok burner
Nozzle
Number
Bypass
260
Gap
185
Gap
145
Gap
340
Gap
240
Gap
175
Gap
135
Gap
315
Gap
5.
Refit the control knob for the gas burner.
Power
(W)
min. (W)
3000
800
500
1000
400
3900
1600
3000
800
500
1000
400
3900
1600
Type of burner
Power
(W)
High output burner 3000
Standard burner
1750
Economy burner
1000
Wok burner
3700
High output burner 3000
Standard burner
1800
Economy burner
1000
Wok burner
3900
Your appliance must be operated at these pressure values. All
information on the rating plate refers to these pressure values.
The manufacturer does not accept any liability for operability,
power of the appliance or for other risks if the appliance is
operated at pressure values other than those values specified
for the appliance.
Note: If you are operating the appliance with liquefied gas, use
a gas pressure regulator. The pressure regulator must be
connected and maintained by a licensed technician.
Consumption max.
G20
G30
283 l/h
167 l/h
97 l/h
359 l/h
218 g/h
131 g/h
73 g/h
284 g/h
Power
Consumption max.
min. (W)
G110
800
648 l/h
500
384 l/h
400
219 l/h
1400
833 l/h
800
500
400
1400
G31
214 g/h
129 g/h
71 g/h
278 g/h
G120
582 l/h
354 l/h
201 l/h
764 l/h
35