Download Inhoudsopgave Inhoud Print deze pagina

Assembling The Heater - Qlima GFA 1010 Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

• Always use a suitable and approved 700

ASSEMBLING THE HEATER

The manufacturer is not responsible for any harm or damage if attention is not
paid to the points described above.
The use of this product and the elements required for that purpose is entirely at
the end user's own risk.
GAS REQUIREMENTS
Use propane, butane or LGP only. See rating label on the appliance.
LEAK TESTING
4
22
All manuals and user guides at all-guides.com
Always store the gas containers in a cool,
dry and dark place.
mbar medium-pressure regulator. In case
of any doubt contact your local dealer.
The appliance requires approved gas hose in <150 cm length and a gas regu-
lator. The hose and regulator assembly must conform to local standard codes.
Regulator maximum inlet pressure must not exceed 690 kPa
Regulator outlet pressure to be 700 mbar (70 kPa) depending on countries.
The installation must conform to local codes, or in the absence of local codes,
to the standard for the storage and handling of liquid petroleum gases.
A dented, rusted or damaged gas cylinder may be hazardous and should be
checked by an authorized dedicated gas specialist,
Never use a gas cylinder with a damaged valve connection.
The gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder.
Never twist the flexible tubes and hoses.
Never connect an unregulated gas cylinder to the heater.
Disconnect the gas cylinder when the heater is not use.
Gas connections on the heater are leak tested at the factory prior to ship-
ment. A complete gas tightness check must be performed at the installation
site due to possible mishandling in shipment and/or installation or because
of excessive pressure being applied to the heater. The heater must be chec-
kedwith a full cylinder.
1. Make sure the safety control valve is in the OFF position.
2. Make a soapy water solution of one part liquid detergent and one part
water. The soapy water solution can be applied with a spray bottle, brush or
rag to all gas connections. Soap bubbles will appear in case of a Ieak.
WARNING: Never leak test while smoking!
WARNING: In the event of gas leakage, the appliance shall not be used or if
alight, the gas supply shall be shut off and the appliance shall be investigated
and rectified before it is used again.
3. Turn the gas supply ON. And check all the connections with the soapy
water solution. No bubbles may appear!
4. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then
turn the gas supply ON and recheck. Contact your dealer or gas supplier for
assistance if bubbles continue to appear.

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Gfa 1015Gfa 1030e

Inhoudsopgave