8.5 DIP switch settings
WARNING
High voltages
Danger of fatal electric shock.
Ensure safe isolation from the power supply
X
X
The power settings of the charging station are configured
with DIP switches (see Fig. 08).
DIP switch up/ON = 1
DIP switch down/OFF = 0
Factory setting: 1100
Changes to the DIP switch settings become active
after restarting the charging station.
DIP switches 3 and 4 are set at the factory. Switches
3 and 4 must be left set to 0.
DIP-switch settings
Switch
1
2
3
16 or
Descrip-
1- or
32 A
Factory setting
tion
3-phase
per
phase
16 A
0
0
0
1-phase
32 A
0
1
0
1-phase *
16 A
1
0
0
3-phase
32 A
3-phase
1
1
0
factory
setting **
8
* The charging current is limited to 20 A in the factory in
the case of a 22 kW variant with 1-phase charging. See
Chapter 9.3 on page 9 „Deactivate charging current
limit".
* The charging current is already limited to 16 A in the
factory in the case of an 11 kW variant.
** A Webasto Pure programmed for 11 kW cannot be set
to 22 kW with the DIP switches.
8.6 Initial start-up
Safety check
Document the results of the checks and measurements
carried out during initial start-up corresponding to the
applicable installation requirements and standards.
The local regulations relating to operation, installation and
environmental protection also apply.
Start-up procedure
Capacity
Remove material residues from the connection area.
X
X
4
Check that every screw is correctly tightened and every
X
X
clamp is correctly engaged.
Fit the lower cover.
X
X
Fit and tighten the mounting screws for the lower cover.
X
X
(See Fig. 03)
Switch on power supply.
X
X
0
3.7 kW
– Start sequence is activated (duration up to 60
seconds)
0
7.4 kW
– LED indicator flashes red/green/blue at 1 second
intervals. See Fig. „05" - operating status N1.
0
11 kW
If necessary, unlock charging station with key-operated
X
X
switch.
0
22 kW
Perform initial operation check and record measured
X
X
values in test log. An EV simulator is used for the
measurement at the charging coupling.
Simulate and test the individual operating and protection
X
X
functions with the EV simulator.
Connect the charging cable to the vehicle.
X
X
– The LED changes from blue to green.
9 Settings
It is necessary to complete the following procedures
within a certain time, therefore read through all the
steps before starting the procedure.
The LED colours blue and green can be dimmed. The
brightness of the red warning colour can not be changed.
9.1 To activate programming mode
X
3
Charging station switched on.
X
3
LED indicator is blue.
X
3
Key-operated switch set to ON.
X
3
No vehicle connected.
Set key-operated switch from ON to OFF (Fig. 07); wait
X
X
until LED indicator flashes blue 3 times.
Set key-operated switch from OFF to ON (for max. 3
X
X
seconds).
Set key-operated switch from ON to OFF; wait until LED
X
X
indicator flashes blue once.
Set key-operated switch from OFF to ON (for max. 3
X
X
seconds).
Set key-operated switch from ON to OFF; wait until LED
X
X
indicator flashes blue 3 times.
When the LED indicator flashes for the fourth time it
X
X
changes to white and the charging station automatically
assumes programming mode.
Programming mode activated
The charging station runs through two options 10 times.
If no option is selected with the key-operated switch after
the charging station has run through them 10 times, pro-
gramming mode will be deactivated automatically without
any changes.
9.2 Dim LED indicator (option 1)
X
3
Programming mode activated
The LED indicator flashes white in the following sequence
once:
– 0.5 s OFF;
– 0.5 s ON;
After a four second pause the LED indicator switches to
yellow for one second:
Webasto Pure