3.4 Control
The control switching points are set in Setting mode.
Setting:
Press and hold the Print button and then press the On/Off button for 5 seconds
until appears.
With the Tare button, raise this value to then press the Print button to
store. Position 01 in is displayed
Then, press the Print button to open the input field for the reference weight
value.
Using the Tare button and Function key, set a number value in the flashing
space.
You can use the Zero button to move by one decade from right to left.
After setting the reference value, store with the Print button, position 02 in
is displayed.
Then, press the Print button to open the input field for the weight positive
tolerance.
Use the T, F and Zero buttons to set a number value for the positive tolerance,
as for the reference weight.
After setting the weight positive tolerance, store with the Print button, position
03 in is displayed.
Then, press the Print button to open the input field for the weight negative
tolerance.
Use the Tare, Function and Zero buttons to set a number value for the negative
tolerance, as for the reference weight.
After setting the weight negative tolerance, store with the Print button, position
04 in is displayed.
Press the Zero button, appears on the display.
To save the setting and exit, press and hold the Print button then briefly press
the Zero button. The display returns to weighing mode.