Download Print deze pagina

elco AEROTOP MONO M-RX Gebruiksaanwijzing pagina 22

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 36
Product description
System interface
1. back button
(previous screen)
2. knob
3. OK button (to confi rm operation or
access main menu)
4. DISPLAY
Display symbols:
- (
)
Summer / DHW settings
- (
) Winter
- (
)
Heating only / CH settings
- (
)
Cooling
- (
)
OFF, system off
- (
) Time program
- (
) Manual operation
- (
)
Desired room temperature
- (
Room temperature
detected
- (
)
Desired room temperature
override
- (
)
Outdoor temperature
- (SCI)
SCI function enabled
- (
)
HOLIDAY function enabled
- (
)
Central heating active
- (
)
Domestic hot water active
- (
)
Error indication
- (
)
Menu
- (
)
System performance
- (
)
Screen setting
- (
)
Floor Heating
- (
)
Circulation pump
- (
)
Diverter valve
- (
S2)
Low indirect cylinder sensor
- (
S3)
High indirect cylinder
sensor
- (
S4)
Under-fl oor heating system
thermostat
- (
)
Anti-frost function
- (
)
Thermal Cleanse Function
- (
)
Confi gurable device
- (
)
Heat pump
- (
)
Heating element 1
- (
)
Heating element 2
- (
)
Heating element excluded
- (
)
Excludes the heating
element during the high
energy rate period, in the
presence of the
appropriate signal only
in heat pump systems
- (
)
Sets the reduced set-point
during the high energy rate
period, in the presence of
the appropriate signal only
22 / GB
in heat pump systems
- (
)
BOOST mode
- (
)
Silent mode
- (
)
Special function
- (
)
Dehumidifi cation
- (
)
Smart Grid Ready
- (AP)
Access Point confi guration
- (
)
Gateway connected to
internet
- (
)
Gateway not connected to
router
- (
)
Gateway connected to
router but not to the
internet
- (
)
Software update in progress
Initial start-up
The fi rst time the Remocon Plussystem in-
terface is connected, the user is required to
choose certain basic settings.
First, you will need to select the user interfa-
ce language.
Turn the knob and select the desired lan-
guage, then press the OK button to confi rm.
Move on to setting the date and time. Turn
the knob to make a selection, press the OK
button to confi rm your selection, turn the
knob to set the value.
Press the OK button to confi rm.
Save the settings by pressing OK.
Press the OK button to access the Menu. Use
the knob in the centre to scroll through the
menu list and select a parameter, then press
OK to confi rm.
OK
1
2
3
NOTE
Some parameters are protected with an ac-
cess code (safety code) which protects the
system settings from unauthorised use.
The system interface REMOCON PLUS
is compatible with REMOCON NET* the
service designed and manufactured by
Elco to provide a whole new experience in
using a domestic heating and water system.
Remocon NET allows you to start, stop
and check the temperature of domestic
heating and water anytime, anywhere from
a smartphone or PC.
It allows you to constantly monitor energy
consumption to ensure you save on your
gas bill. It also notifi es in real time if there is
a boiler failure. Also, when the teleassistance
service is activated, the service centre will
be able to solve most problems remotely,
or arrange an appointment at your best
convenience.
For more information, visit the site
www.remocon-net.com
*availability of the service must be verifi ed with your trusted dealer
4

Advertenties

loading