15 Commissioning

15.1 Energy-saving function

‰ When the mains plug has been connected, the ma-
chine is in Standby mode and the On LED 18 flashes
every 3 sec.
‰ If the device is in Standby mode, then it can be
switched on using the On/Off button 17.
‰ If the device is switched on, then it can be switched to
Standby mode using the On/Off button 17.
‰ If the device is not used for 30 min., then it automati-
cally switches to Standby mode. (BasicPlus)
Switch off Auto-Standby function
(BasicPlus)
 Press button 17 for 10 sec.
9 The three LEDs 13, 14 and 15 are lit for 5 sec., the
Auto-Standby function has been switched off.
Switch on Auto-Standby function
(BasicPlus)
 Press button 17 for 10 sec.
9 The two LEDs 13 and 15 are lit for 5 sec., the Auto-
Standby function has been switched on.
Switch on / off Auto-Standby function
(ControlPro)
‰ See chapter "15.4 Call secondary parameters (Con-
trolPro)" on Page 27.
Before switch-on, ensure that neither the
electrode holder nor the electrode is touching
the welding table, the workpiece or another
electrically-conductive object, to ensure that
you do not unintentionally ignite arcing on
switch-on. An unintentionally ignited arc can
damage the electrode holder, the welding ta-
ble, the workpiece and the machine.
15.2 Electrode welding process
Switch on the system
 If necessary, switch the system on by pressing button
17 for 2 sec.
 Keep pressing button 16 until the electrode operating
function is selected.
9 The electrode icon MMA or CEL (LED 13 or 14) lights
up.
 Use control knob 12 to set the desired welding current.
- 26 -
Arc ignition
 Briefly touch the workpiece at the point to be welded
using the electrode and lift the electrode a little.
9 The arc burns between the workpiece and the elec-
trode.
Hotstart
‰ In the electrode welding method, a hotstart of 125 %
of the set welding current is used for 1 second for igni-
tion. Like the welding current, the hotstart is limited to
a maximum of 150 A.
Guide values for current intensity
Electrode Ø
[mm]
1.5
2.0
2.5
3.2
4.0
15.3 TIG welding process
Switch on the system
 If necessary, switch the system on by pressing button
17 for 2 sec.
 Keep pressing button 16 until the TIG operating func-
tion is selected.
9 The TIG icon (LED 15) lights up.
 Use control knob 12 to set the desired welding current.
Arc ignition
 Open the valve 56 on the TIG welding torch.
 Briefly touch the workpiece with the tip of the elec-
Â
trode at the point to be welded.
 Lift the electrode a little.
Â
9 The arc burns between the workpiece and the elec-
trode.
Upslope
‰ A short-circuit current of 60 A is used for igniting during
the TIG welding process. The upslope takes place with
115 A/s until the set welding current is reached.
909.2759.9-05
Commissioning
Recommended current
intensity [A]
20...40
35...60
45...100
75...140
130...190
VIII