PUMP INSTALLATION: USE AND REGULATION
Proceed as follows to install the pump: 1) Connect the joint to the pump outtake to
which you can connect the hose with the appropriate diameter. 2) Place the pump
in an area of the pond, easily accessible for the maintenance operations. 3) If the
pump is used submersed and not in line, it must be always fully submersed. (Pic. D)

IN LINE APPLICATIONS

It is recommended to place the pump in spaces where there is a proper ventilation
and the pump is not directly exposed to heat sources. Place the pump so as to
prevent too long idraulic pipings, which would reduce its performance. Do not
position the pump above the water level (Pic. E) because it is not self-priming
and the risk of the pump to run dry. The risk of invisible air bubbles creating a
vacuum area is very high. Damages which are caused by the pump running dry are
excluded from warranty. To maximize the pump's efficiency, choose a straight inlet
tube without elbows (Pic. F). We suggest an Inlet and outlet tubes with diameter
equal or bigger than the diameter of the threaded pipe included (Pic. G). Do not use
the pump leaving the outlet totally closed. A minimum water flow is necessary to
keep the inner motor cool without running dry (Pic. H).
MAINTENANCE
For the periodic maintenance of the pump, unplug the pump from the electric
socket and then remove the pump from water. 1) Lift the plastic ring of the pump's
volute pulling the tab outwards (Pic. I). 2) Remove the ring (Pic. J). 3) Remove the
volute of the pump by turning and simultaneously pulling forward (in the case of
fouling this may take more pressure). 4) Pull out the complete rotor set (Pic. K).
5) Rinse each part with water, using a soft brush to remove the deposit. 6)
Then assemble everything in the inverse order. 7) Put the ring in place with the
biggest teeth facing the pump and close it by pressing on the tab until you hear
a "click". (Pic. L). Any damage to the o-rings, even small, can seriously endanger
the pump performance. In this case, it is best to replace them. IMPORTANT: The
build-in circuit board of the pump has been programmed to provide 3 levels of
protection: Protection against rotor's blockage: In case of malfunction which
causes the lock of the rotor (due to excessive dirt or other) or of operating without
water, the pump, after 20 attempts to start, followed by a short interval of time,
and other 20 attempts will stop automatically. If this does not happen, the pump
will automatically go on standby, the electronic board will remain powered but the
engine will shut down. In this case to restart the pump you need to remove and
re-insert the plug into the power outlet. Dry running protection and thermal
protection: motor's protection in case of functioning without water. The pump
stops when it works without water, or if there is a locked rotor. When the pump is
taken out from the water, the motor stops. ATTENTION: do not underestimate the
power of the magnet. If you slightly loose the grip and the axis hits the rear bearing,
the risk to damage the bearing is very high. A damage axis and bearing causes
high reparation costs.