x 2
para . 1
para . 2
para . . . .
logic
logic. 1
logic. 2
logic. . . .
radio
hidden button
add. start
erase 64
COD RX
v
PRG
default
ITA
OK
language
- +
FRA
OK
- +
DEU
OK
- +
ENG
OK
- +
esp
OK
stat
vers
OK
OK
- +
OK
n. cycles
- +
OK
n. Re otes
ACCESS TO MENUS Fig. 1
release
desired button
PRG.
+/-
OK
2 2 F D
OK
1 A 9 C
DIAGNOSTICS
DESCRIPTION
CODE
START input activated
stre
STOP input activated
stop
attivazione ingresso PHOT
phot
SAFETY EDGE input activated
bar
SAFETY EDGE input activated on slave motor
bar2
(opposite leaves connection)
CLOSE input activated
cls
OPEN input activated
open
TIMER input activated
ti e
opening limit switch input activated
svo
closing limit switch input activated
svc
enabling input reference opening
refo
. . .
enabling input reference closing
refc
+/-
photocell test error
Er01
board hardware test error
Er1x*
0000
+/-
Encoder Error
er2x*
reverse due to obstacle
er3x*
thermal cutout error
Er4x*
00
anomaly in communication whit remote devices check Scs1 serial connections
+/-
Er5x*
running off battery
er61
*
limit switch error
Erf
x
* X = 0,1,...,9,A,B,C,D,E,F
35. 4 0
Set torque threshold
Maximum instantaneous motor torque
See PARAMETERS MENU
See LOGIC MENU
ok 01
0 1
OK
DIAGNOSTICS and WARNINGS
Scroll up
Scroll down
Confirm/Switch on display
Exit Menù
NOTES
check photocell connection and/or logic
settings
check connections to motor
motor or signal encoder power leads inver-
ted/disconnected
check for obstacles in path
Allow motor to cool
check limit switch connections
GIOTTO 30-60 S BT / GIOTTO 30-60 BT -
23