The included mounting material is suitable
o
for ordinary solid concrete or masonry
construction . Check which mounting material
is suitable for your chosen mounting surface . If
necessary, seek expert advice .
˜ Installing the product
Make sure you will not be drilling into
 
electrical, gas or water lines inside the wall .
Use a power drill to drill the holes into the
wall . Always observe all safety instructions for
the power drill in the manual for the power
drill . Death or injury due to electric shock may
otherwise result .
When selecting the mounting location, pay
attention to the following:
Make sure that the spotlight 
o
desired area . You can move the spotlight 
vertically .
Make sure the motion detector 
o
desired area . The motion detector 
maximum coverage range of 12 m, with a
coverage angle of about 180° (depending
on the mounting height – a height of 2 .5 m is
ideal) (fig . E) .
Make sure the motion detector 
o
illuminated at night by street lighting . This can
influence its functioning .
During mounting, proceed as described below:
1 . Unscrew the locking screws 
crosshead screwdriver to detach the mounting
bracket 
from the spotlight 
[
7 ]
2 . Hold the mounting bracket 
horizontal against the wall (possibly with a
spirit level) . Mark the drill holes .
3 . Drill the drill holes (Ø 6 mm) . Push the wall
plugs 
into the drill holes (fig . A) .
[
6 ]
4 . Secure the mounting bracket 
using the mounting screws 
the tight fit .
5 . Run the connection cable (not included in the
product), type H05RN‑F 3G 1 .0 mm², through
the cable gland 
12 ]
[
the connection terminal 
length of the connecting wires, refer to fig . C .
8
GB/IE/NI
illuminates the
1 ]
[
[
1 ]
covers the
[
8 ]
has a
[
8 ]
is not
[
8 ]
by using a
[
2 ]
.
1 ]
[
so that it is
7 ]
[
onto the wall
[
7 ]
provided . Check
5 ]
[
and terminal cover 
to
11 ]
[
. For the suitable
13 ]
[
6 . Open the connection terminal 
crosshead screwdriver to loosen the screws .
7 . Connect the connection cable with the
connection terminal 
markings on the connection terminal 
live, N for neutral and
(fig . C) .
8 . Close the connection terminal 
the screws . Make sure the seal ring 
correctly installed (fig . B) . Tighten the terminal
cover 
and cable gland 
11 ]
[
connection cable .
9 . Use a crosshead screwdriver to attach the
spotlight 
to the mounting bracket 
1 ]
[
the previously removed locking screws 
spring washers 
, and tooth lock washers 
[
3 ]
(fig . A) .
10 . Align the spotlight 
1 ]
[
direction . The motion detector 
rotated approx . 150° horizontally and
approx . 180° vertically .
11 . Reinsert the fuse or switch the circuit breaker
back on . The product is now ready to use .
˜ Operation
˜ Adjusting the motion detector
Depending on the pre‑adjustments of the
o
motion detector 
[
8 ]
itself on for a certain period of time as soon
as the motion detector 
These pre‑adjustments are made using the
3 controllers on the underside of the motion
detector 
(fig . D) .
8 ]
[
˜ Setting the lighting duration
Turn the rotary control TIME 
o
to increase the duration of the illumination . The
lighting duration can be adjusted within a time
window of approx . 10 seconds to 7 minutes .
˜ Adjusting the sensitivity of
the sensor
Turn the rotary control SENS 
o
to increase the sensitivity of the sensor .
by using a
[
13 ]
. Pay attention to the
13 ]
[
(L for
[
13 ]
for the earth wire)
by fastening
[
13 ]
is
10 ]
[
to fix the
[
12 ]
with
[
7 ]
,
[
2 ]
into the desired
can be
[
8 ]
, the spotlight 
will switch
1 ]
[
detects movement .
[
8 ]
anti‑clockwise
16 ]
[
anti‑clockwise
15 ]
[
4 ]
[