INSTALLATION
In order to adapt the cooker to burn a different
type of gas, you should:
exchange nozzles (see tables below),
adjust the "economical" flame.
Burner of DEFENDI type (according to the "Defendi" symbol on burner components)
Type of gas
G20 2E - 20mbar
G25 2L - 25mbar
G30 3B/P - 50mbar
G30 3B/P - 30mbar
Burner flame
Full
Economical
In order to perform adjusting operations, take off the knobs.
All manuals and user guides at all-guides.com
auxiliary
gas injector
diameter [mm]
nominal
thermal power
1,00 kW
0,77
0,46
0,50
Re-arming from liquid
to natural gas
1. Exchange a burner noz-
zle for the appropriate type
according to the nozzle
table.
2. Unscrew an adjusting
bolt slightly and adjust the
flame size.
Caution!
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specified on their data plates and
guarantee cards.
Burner
medium
gas injector
diameter [mm]
nominal
thermal power
1,75 kW
0,97
0,60
0,65
Re-arming from natural
gas
1. Exchange a burner
nozzle for the appropriate
type according to the noz-
zle table.
2. Screw in an adjusting
bolt slightly and check the
flame size.
16
large
gas injector
diameter [mm]
nominal
thermal power
3,00 kW
1,29
0,79
0,87
gas