4. CONTROLS
Button Function
A
Changes the intensity of the Lighting each time
the Button is pressed, in cycle, passing via Off.
B
Motor off.
Enables / Disables Keyboard Lock mode if pres-
sed and held for 5 seconds.
C
Activates speed one.
D
Activates speed two.
E
Activates the speed Intensive 1. This speed is ti-
med to run for 10 minutes. At the end of this time
the system will return to the speed set previously.
It is disabled by pressing the Button or turning the
Motor off.
F
Activates the speed Intensive 2. This speed is
timed to run for 8 minutes. At the end of this time
the system will return to the speed set previously.
It is disabled by pressing the Button or turning the
Motor off.
G
Activates / Deactivates Delay mode, with automa-
tic shutdown of the Motor and the Lighting after
15 minutes. It is disabled by pressing the button
or turning the motor off.
Pressing and holding the button for 5 seconds
enables the remote control and the H2H function.
Pressing and holding the button for 5 seconds
disables the remote control and the H2H function.
H
With the filter alarm triggered, press the button to
Reset the alarm. These indications are only visible
when the motor is turned off.
Press and hold the button for approximately 5
seconds, with all the loads turned off (Motor and
Lights), to turn the Activated Charcoal Filter alarm
on/off.
Led
-
The Leds indicating the Speed of the motor
turn off.
All the Leds light up in cycle and run a
start-up sequence.
The Leds indicating Speed one and Motor
Off turn on.
The Leds indicating Speed two and Motor
Off turn on.
The LED flashes.
The LED flashes.
The Led lights up.
2 flashes from Leds on Buttons B+C.
1 flash from Leds on Buttons B+C.
When the procedure terminates, the indica-
tion shown previously turns off:
Led H on = Indicates the need to wash the
metal grease filters. The alarm is triggered
after the Hood has been in operation for
100 working hours.
Led H flashing = Indicates the need to
change the activated charcoal filters, and
also to wash the metal grease filters. The
alarm is triggered after the Hood has been
in operation for 200 working hours.
2 flashes from Leds on Buttons B+H = A.C.
filter alarm activated.
1 flash from Leds on Buttons B+H = A.C.
filter alarm deactivated.
ENGLISH
5