INSTALLATION
Surface burners applied do not require adjust-
ment of primary air. A correct flame has dis-
tinct internal cones of blue and green colour.
A short, humming flame or long, yellow and
smoking one, without clearly outlined cones,
shows improper quality of gas in the house-
hold piping or a damaged or soiled burner.
In order to check a flame, heat a burner for
around 10 minutes with a full flame, and next
turn the valve knob to the economical flame
position. The flame should not go out or jump
onto the nozzles.
Exchange of a burner noz-
zle – unscrew the nozzle
with special socket span-
ner No 7 and replace with
a new one according to a
type of gas (see tables).
Gas supply to surface burners is opened and
set by knobs, fig A. Knobs should be adjusted
with the burner switched on and set to the
economical flame position, using an adjust-
mentscrewdriver of the 2.5 mm size.
All manuals and user guides at all-guides.com
A professional installer must adjust the small
flame on-site in your home. The adjustment
depends on the type of gas and its pres-
sure.
Caution!
After adjustment is completed, place
a label indicating the type of gas to
which the cooker is now adapted.
16
Fig. A
DEFENDI
knob