INSTALLATION
DEFENDI-Burner
Type of gas
G20 2E - 20mbar
G25 2L - 25mbar
G30 3B/P - 50mbar
G30 3B/P - 30mbar
In order to perform adjusting operations, take off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the oven chamber floor.
The procedure for changing the gas type
Flame
Burner
full flame
hob
small flame
full flame
oven
small flame
All manuals and user guides at all-guides.com
auxiliary
gas injector
diameter [mm]
nominal
thermal power
1,00 kW
0,77
0,46
0,50
Conversion from LPG
to natural gas
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
1.Replace burner nozzle with
the appropriate nozzle accor-
ding to the table.
2.Gently tighten the adjusting
screw and adjust the flame.
The temperature in the oven
should be 150
Burner
medium
gas injector
gas injector
diameter [mm]
diameter [mm]
nominal
thermal power
thermal power
1,75 kW
0,97
0,60
0,65
Conversion from natural
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and adjust the
flame. The temperature in
C.
the oven should be 150
O
C.
O
15
large
oven
gas injector
diameter [mm]
nominal
nominal
thermal power
3,00 kW
2,80 kW
1,29
1,30
0,79
0,75
0,87
0,84
gas to LPG