INSTALLATION
Caution!
The cooker may only be connected
to a liquid gas cylinder or the existing
gas supply by an authorised fitter,
observing all safety rules.
The cooker has threaded ½" pipe connec-
tor.
The connector must be screwed in with a dy-
namometric spanner with a maximum torque
of 20 Nm. It is recommended to seal connec-
tions with a teflon sealing tape. If the torque
is too high or tow is used, the connection be
damaged and become leaky.
When connecting the cooker to the gas sup-
ply, a metal tip of at least 0.5 m length with
an end for a 8x1 mm hose should be screwed
onto the R1/2" terminal. In order to screw the
tip in, you should unscrew the spring of the
cover hinge. The gas hose should not touch
metal elements of the cooker back shield.
Important!
Each time you replace a reducer
carry out technical inspection of the
cooker that covers gas valves and
proper operation of the flame failure
cut-off device.
Caution!
On completion of the cooker installa-
tion, the tightness of all connections
should be checked, e.g. applying
water with soap.
Do not use fire to check tightness.
All manuals and user guides at all-guides.com
Electrical connection
The cooker is manufactured to work with
a one-phase alternating current (230V
1N~50 Hz) and is equipped with a 3
x 1,5 mm
connection lead of 1.5 mm
2
length with a plug including a protection
contact.
A connection socket for electricity supply
should be equipped with a protection
pin and may not be located above the
cooker. After the cooker is positioned, it is
necessary to make the connection socket
accessible to the user.
Before connecting the cooker to the
socket, check if:
- the fuse and electricity supply are able to
withstand the cooker load,
- the electricity supply is equipped with an
efficacious ground system which meets
the requirements of current standards
and provisions,
- the plug is within easy reach.
Adapting the cooker to another
type of gas.
This operation may only be carried out by an
appropriately authorised fitter.
If the gas the cooker is to be supplied with
differs from the gas provided for the cooker
by the manufacturer, that is G20 20 mbar,
burner nozzles must be exchanged and the
flame needs to be adjusted.
In order to adapt the cooker to burn a different
type of gas, you should:
exchange nozzles (see tables below),
adjust the "economical" flame.
Caution!
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specified on their data plates and
guarantee cards.
14