OPERATION

SAFETY

2.
Safety
Risk of injury!
Where children or persons with limited physical, sensory
or mental capabilities are to be allowed to control this
appliance, ensure that this will only happen under su-
pervision or after appropriate instructions by a person
responsible for their safety.
Children should be supervised to ensure that they never
play with the appliance.
Scalding risk!
Steam may escape from the steam pipe on malfunction.
The surface of the fitting may heat up to over 60 °C!
2.1

Test symbols

See type plate on the appliance.
3.

Unit description

The appliance is used to prepare boiling water.
It contains approx. 30 cups (1 cup = 167 ml) of boiling water.
Cold water is automatically added on withdrawal. This is automati-
cally heated up to boiling point.
The unit is switched to "set-back operation" (4 - 5 K) if water is not
drawn for some time. When water is drawn, automatic heating
follows up to boiling point.
The power supply must be interrupted to switch the unit off. An
existing on/off switch is recommended for switching the unit.
The unit's external housing consists of coated dirt-resistant stain-
less steel.
4.
Operation
4.1

Operating display

4
3
1 Operating indication "ON"
2 Operating indication "READY"
3 Outlet
4 Tap
Operating display
ON
lights-up unit operative
READY
lights-up boiling water available
flashes
automatic boiling point detection:
on starting up
following voltage interruption
repetitive after approx. 4 weeks
WWW.STIEBEL-ELTRON.COM
4.2

Taps

4.3

Heating up time

The heating up time (boiling point) on first start-up is approx.
24 minutes (with cold water temperature of 10 °C). Following first
start-up, heating up is automatic whenever water is drawn.
5.

Maintenance and care

A damp cloth suffices to clean the housing.
Don't use scouring or solvent cleansers!
5.1

Scaling

The water is ejected on high temperatures in the hydrolith (scale).
The qualified installer will check the appliance from time to time
for scale and descale it if necessary. The frequency depends on
local water quality and user habits. An initial check is recom-
mended after approx. 6 months. The necessary scaling cycle can
be adjusted after six months or so.
6.

What to do if ...

6.1

... the appliance develops faults

Fault
Unit won't heat up
Water output sub-
stantially reduced
Unit will nottop up
1
Outlet won't close
2
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000).
Cause
» Remedy
No power supply; no ON
Check fuses in the domestic
indication
installation.
Water supply blocked
Check water supply.
Scale / soiling
Check water supply.
Low water pressure
Check water supply.
Scale in the output
Clean outlet.
KA |
15