Installation
Placement
! NOTE: For optimized viewing angle of the 昀氀ame, it is recommended that the bottom of the unit be
mounted between 5" (13 cm) and 50" (127 cm) from the ground (Figure 2).
Installation in a Bathroom
If this unit is installed in a bathroom, it must be protected by a GFCI receptacle or circuit . If a recep-
tacle is used, it must be readily accessible .
This electrical appliance is NOT watertight . To prevent electric shock, it must be installed as to
prevent water from entering unit, or installed away from showers, tubs, etc . Never locate 昀椀replace
where it may fall into a bathtub or other water container.
Installation Recommendations for Overhanging Objects
For overhanging temperature-sensitive objects, such as a television, a mantel, or artwork, always
follow the recommendations provided by its manufacturer for installation over a heater.
Fresh Inlets
CAUTION: Failure to include a fresh inlet will result in poor 昀氀ame performance and damage to the
昀椀replace .
A fresh inlet is required . The inlet must allow for the path to reach the underside of the unit. This
will have to be accounted for in the framing and drywall installation . See the table below for inlet
requirements for each model . See Figure 3 for examples on incorporating fresh inlets in the instal-
lation .
If the inlet is concealed using a grille, the covered area must be compensated for by having a larger
opening .
Model
OLF46-EU
OLF66-EU
OLF86-EU
Preparing the Firebox for Installation
The unit is provided with mounting brackets attached (Figure 4) . Remove the mounting brackets
before installation . They will need to be reinstalled during installation once the 昀椀rebox is placed into
the framing .
Framing
Prepare a wall with a framed opening, following the dimensions in the table below . Openings be-
neath the unit are required in order to allow for 昀氀ow to reach the underside of the unit (Figure 6).
MODEL
Width (min)
OLF46-EU
48" 1219mm
OLF66-EU
68" 1727mm
OLF86-EU
88" 2235mm
Framing Dimensions
Height
A
B
31 3/4"
806mm
inlet area required
80 in²
120 in²
160 in²
Depth (min)
C
12"
46 3/16" 1174mm
305mm
66 3/16" 1682mm
86 3/16 " 2190mm
21
516 cm²
774 cm²
1032 cm²
Drywall Opening
Height
Width
D*
17 1/2"
445mm
E*