All manuals and user guides at all-guides.com
Measures for problem rectification
Problem
Coffee has no cream
The optimum quality of the cream is not achieved until you
have used your coffee pad machine a few times.
Sieve insert calcified?
> In this context, see Chapter "5.4.2 Coffee spout cassette with sieve insert" on page 31 .
> Clean and descale the sieve insert regularly.
Coffee nozzle continues
Locking knob in home position
to drip for a long time.
> After brewing, if you always set the locking knob back in the
home position
No milk foam, only hot milk
Steam nozzle wrongly assembled?
> Check whether the steam nozzle is firmly screwed into the steam outlet.
Milk used too hot?
> Use cold milk (4°C to 8°C).
Milk hose adapter not inserted correctly?
> Push the milk hose adapter firmly into the mixer until it comes to a stop.
Rectification measure
?
, prolonged dripping is prevented.