POSITIONING AND CONNECTiNG THE DEVICE
EN
Please Note!
•
The device must have clearance of at least 1 m above it and to all sides and be placed
on a dry, even, solid and moistureresistant surface.
•
Only connect the device to a plug socket that is properly installed and matches the
technical data of the device. The plug socket must also be readily accessible after
connection so that the connection to the mains can quickly be isolated.
1. Position the device at the location you want. When you do this, push the device
carefully so that the water in the water tank (10) does not spill out.
2. Secure the device to stop it rolling away by moving the castor lock (8) on the two front
castors (9) to the ON position.
3. Fully unwind the connecting cable and connect it to an easily accessible plug socket.
You will hear a beep. All elements on the control panel (2) will light up and go out with
the exception of the operating lamp POWER (25). The device is in standby mode.
USE
Please Note!
•
Do not use the device without water. The pump could be damaged.
•
Do not move the device during operation. Before the location of the device is changed,
switch off the device and disconnect it from the mains power.
•
Do not operate the device unsupervised so that you can intervene immediately if there
are any faults.
1. Fill the water tank (10) (see the "Filling the Water Tank" chapter).
2. Position the device at the location you want and connect it (see the "Positioning and
Connecting the Device" chapter).
3. Touch the POWER fi eld (25) to switch on the device. The device starts to operate on
speed level 1. The ionisation ION (18) and the cooling and humidifying function COOL
(24) are activated.
4. Adjust the settings of the device to suit your individual needs (see the "Functional
Overview of the Operating Elements" chapter).
The air flow can be increased or decreased. To do this, move one of the
side levers (15) on the ventilation grille (3) manually up or down. This will
adjust the horizontal slats of the ventilation grille.
5. If the device is no longer going to be used, switch off the device via the POWER fi eld
and pull the mains plug out of the plug socket.
12
CLEANING AND STORAGE
Please Note!
•
No liquid must get into the device (with the exception of the water tray and the water
tank). Never immerse the device in water!
•
Do not use any sharp or abrasive cleaning agents or cleaning pads to clean the device.
These may damage the surfaces.
•
Make sure that the device is not connected to the mains power.
•
Wipe down the device with a soft, damp cloth. Remove more stubborn dirt with a little
mild detergent.
•
Keep the device operational and clean the honeycomb filters (4) if necessary.
•
If the device is not going to be used for a prolonged period and before storing it away,
it is essential to remove any remaining water from the water tank (10).
•
Store the device in a clean, dry place so that it is protected and is out of the reach of
children and animals when it is not in use.
CLEANING AND STORAGE
Cleaning the Honeycomb Filters
•
When rinsing the honeycomb fi lter, the water pressure must not be too great and the
jet of water must not be too strong. This could damage the honeycomb filter.
•
Do not use any acidic or alkaline cleaning agents.
1. Undo the screws on the honeycomb fi lter covers (5) and take them off.
2. Grab a honeycomb fi lter cover on both sides at the top edge, press against the
housing (13) with your thumbs and thus release the honeycomb fi lter cover from the
housing. You need to apply a little force to do this.
3. Lift the honeycomb filter cover up out of the housing at an angle.
4. Tilt the honeycomb filter (4) towards you at the top and lift it up out of the device at an
angle (Picture E).
5. Repeat steps 2 to 4 for the remaining three honeycomb fi lters.
6. Rinse the honeycomb filters under running water.
7. Allow the honeycomb filters to dry completely.
8. Insert the honeycomb filters into the device.
9. Place the honeycomb filter covers in the
housing and press them against the housing
by their top edges. When you do this, make
sure that the locking lugs at the bottom
of the honeycomb filter cover fit in the
corresponding recesses in the housing.
10. Fix the honeycomb filter covers in place with
the screws.
EN