7
Specifications
Function
DC voltage
(auto-ranging)
Input Impedance: 7.8 MΩ
Maximum Input: 1000 VDC or 1000 VAC rms
Function
AC voltage
(auto-ranging)
Input Impedance: 7.8 MΩ
AC Response: 50 Hz ...400 Hz
Maximum Input: 1000 VDC or 1000 VAC rms
Function
DC current
Overload protection: 10 A / 600 V Fuse.
Maximum input: 10 ADC or AC rms on 10 A range.
Function
AC current
Overload protection: 10 A / 600 V Fuse.
AC response: 50 Hz ...400 Hz.
Maximum input: 10 ADC or AC rms on 10 A range.
48
www.nieaf-smitt.com
Range
Resolution
400.0 mV
0.1 mV
4.000 V
40.00 V
400.0 V
100 mV
600 V
Range
Resolution
400.0 mV
0.1 mV
4.000 V
40.00 V
400.0 V
100 mV
600 V
Range
Resolution
10 A
10 mA
Range
Resolution
10 A
10 mA
1 mV
10 mV
1 V
1 mV
10 mV
1 V
Accuracy
+ (0.5 % + 2 d)
+ (1.2 % + 2 d)
+ (1.5 % + 2 d)
Accuracy
+ (1.5 % + 15 d)
+ (1.2 % + 3 d)
+ (1.5 % + 3 d)
+ (2.0 % + 4 d)
Accuracy
+ (2.5 % + 5 d)
Accuracy
+ (3.0 % + 7 d)