6.1
Battery installation
WARNING: To avoid electric shock, disconnect the test leads from
any source of voltage before removing the battery cover.
1.
Turn power off and disconnect the test leads from the meter
2.
Open the rear battery cover by removing two screws (B) using a Phillips
head screwdriver
3.
Insert the battery into battery holder, observing the correct polarity
4.
Put the battery cover back in place. Secure with the screws
WARNING: To avoid electric shock, do not operate the meter until
the battery cover is in place and fastened securely.
NOTE: If your meter does not work properly, check the fuses and
batteries to make sure that they are still good and that they are
properly inserted.
6.2
Replacing fuses
WARNING: To avoid electric shock, disconnect the test leads from
any source of voltage before removing the fuse cover.
1.
Disconnect the test leads from the meter
2.
Remove the protective rubber holster
3.
Remove the battery cover (two "B" screws) and the battery
4.
Remove the 4 "A" screws securing the rear cover
5.
Gently remove the old fuse and install the new fuse into the holder
6.
Always use a fuse of the proper size and value (10 A/600 V fast blow)
7.
Replace and secure the rear cover, battery and battery cover
WARNING: To avoid electric shock, do not operate your meter
until the fuse cover is in place and fastened securely.
47
www.nieaf-smitt.com