Problem and alarm code
The program does not start.
The appliance does not fill with
water.
The display shows
.
The appliance does not drain
the water.
The display shows
The anti-flood device is on.
The display shows
The appliance stops and starts
more times during operation.
The program lasts too long.
The remaining time in the dis-
play increases and skips nearly
to the end of program time.
Small leak from the appliance
door.
The appliance door is difficult
to close.
Rattling/knocking sounds from
inside the appliance.
The appliance trips the circuit-
beaker.
•
Make sure that the appliance door is closed.
•
If the delay start is set, cancel the setting or wait for the end of
the countdown.
•
The appliance has started the procedure to recharge the resin
inside the water softener. The duration of the procedure is ap-
proximately 5 minutes.
•
Make sure that the water tap is open.
•
Make sure that the pressure of the water supply is not too low.
For this information, contact your local water authority.
or
•
Make sure that the water tap is not clogged.
•
Make sure that the filter in the inlet hose is not clogged.
•
Make sure that the inlet hose has no kinks or bends.
•
Make sure that the sink spigot is not clogged.
•
Make sure that the filter in the outlet hose is not clogged.
•
Make sure that the interior filter system is not clogged.
.
•
Make sure that the drain hose has no kinks or bends.
•
Close the water tap and contact an Authorised Service Centre.
.
•
It is normal. It provides optimal cleaning results and energy sav-
ings.
•
Select the TimeManager option to shorten the program time.
•
If the delayed start option is set, cancel the delay setting or wait
for the end of the countdown.
•
This is not a defect. The appliance is working correctly.
•
The appliance is not levelled. Loosen or tighten the adjustable
feet (if applicable).
•
The appliance door is not centred on the tub. Adjust the rear
foot (if applicable).
•
The appliance is not levelled. Loosen or tighten the adjustable
feet (if applicable).
•
Parts of the tableware are protruding from the baskets.
•
The tableware is not properly arranged in the baskets. Refer to
basket loading leaflet.
•
Make sure that the spray arms can rotate freely.
•
The amperage is insufficient to supply simultaneously all the ap-
pliances in use. Check the socket amperage and the capacity
of the meter or turn off one of the appliances in use.
•
Internal electrical fault of the appliance. Contact an Authorised
Service Centre.
Possible cause and solution