4.1 Preparation for installation
Place the machine on an even and stable surface.
Never place the machine on hot surfaces.
Make sure that the machine is on a water-resistant surface in case of water spillage or leakage.
4.2 Electrical connection
Make sure that the local main supply voltage corresponds to the information given on the type
plate on the front panel of the espresso machine.
Plug the machine into a grounded socket only and do not leave it unattended.
Do not roll or bend the power cord.
Do not use an extension cord / do not use a multiple socket.
4.3 Water supply connection
Important
Make sure that the machine is on a water-resistant surface in case of water spillage or leakage.
Make sure that the fixed water connection of your machine is connected to a potable water supply
having an operating pressure ranging between 0 and 1.5 bars. We recommend to use a pressure
regulator and a shut-off valve in case the operating pressure exceeds 1.5 bars or frequently fluctuates.
The shut-off valve should be easily accessible, so that the water flow may be interrupted at any time.
Make sure that the shut-off valve is closed or turned off when the machine is not in use to prevent any
possible water leakage.
Machine in use with direct water connection
The water connecting hose is to be connected to the water supply adapter (image 1).
When using the machine with direct water supply, the valve has to be turned to the side of the water supply adapter
(image 1). The water supply adapter is located in the rear part of the bottom panel (image 1). Additionally, place the
switch behind the drip tray into position "1" (image 2). Please make sure that your water tap is always open during
water-connection usage so that the machine never runs out of water!
Position "0": water tank
image 1
Instruction manual MECHANIKA · TECHNIKA
Place switch into position "1" for
direct water connection
Valve in position for operating
machine with direct water
connection (facing towards the back
side of the machine)
Water supply adapter
23
Position "1": direct water connection
image 2
ENGLISH