• If a frequency converter is used, we recommend to locate it at minimum 3m from the dosing
unit, to use a separate electrical circuit for the converter and the salt electrolysis unit and to
verify interactions between frequency converter and pH – Redox measurement (verify that
pH and Redox do not deviate when switching on-off the convertor).
• All pool equipment external power and adapters must be connected to a power source that
has a residual current device 30mA.
• Make sure all equipment and the swimming pool water are properly grounded. The pool
pipeline is grounded via an in-line grounding to an independent grounding pole.
• Before conducting any maintenance or operation, ensure the salt chlorinator is unplugged,
all machinery is turned off, and the power source is switched off. Simple operation: the unit is
very convenient to operate.
• NEVER make any adjustments inside the dispensing equipment.
• There is no sound alarm on our devices, only an alarm on the screen.
Chemical
• The salt electrolysis must be placed downstream of swimming pool accessories such as
heater, UV lamp, filter, etc
• The salt electrolysis unit will generate chlorine and hydrogen gas. Detectors in the unit, will
stop production in case an excess of these gases are detected. It is therefore mandatory to
install the unit in the direction of the flow. The unit can be installed horizontally or upright
(with flow from bottom to top and the electrolysis cell in the direction of the arrow printed in
the housing of the cell).
• To ensure the smooth operation of the salt chlorine generator, check the electrolysis cell
every three months or after cleaning the filter, whichever comes first.
• Prior to removing the electrolysis cell, ensure the salt chlorinator is closed for 5-10 minutes,
and close the inlet and outlet valves.
• After removing the electrolysis cell, inspect for flake-like sediments, debris, or light-
coloured layering on the inner surface. Clean with water.
O If white calcified substances are present on the titanium plate, soak it in kitchen
vinegar for an hour or more to remove the calcification material.
O If water flushing fails to remove deposits, use a plastic brush for cleaning. Avoid
using a metal brush.
SQ series salt chlorine generator is a device which automatically generates chlorine through
the generator cell. Easy to install and operate, equipped with highly efficient chlorine
production, enable to select time or quick mode control, automatic liquid level detection,
overheat protection, salt level detection, voltage anomalies detection, electrode short circuit
protection, self-cleaning function tips and fault alarm. It is applicable to small pool
disinfection, recycling integrated control equipment.
The Salt Chlorine Generator is elaborately designed:
Two optional outlets make installation more convenient. (see figure 1-2, 1-3).
Removable titanium panels are easy to clean, maintain and install.

PRESENTATION