Follow the steps as indicated below:
1
Brew group in the beginning.
4
Remove the net filter and the gasket
completely.
7
Insert the shower screen into the
group.
10
Then move the filter holder until the
net filter is locked firmly into the
gasket.
The machine can be used again, as described on page 23 of the instruction manual.
Instruction manual MECHANIKA & TECHNIKA PROFI DUE
2
Use a flat screwdriver to lever out the
shower screen and the group gasket.
5
Keep the new spare parts ready at
hand (the rounded side of the group
gasket with ECM print faced
upwards to the brewing group).
8
Take the filter holder without filter.
11
Now you can easily lock the filter
holder into place.
27
3
The net filter and the gasket are now
nearly removed.
6
Clean the group with a brush.
Lock the shower screen firmly into
the gasket.
9
Clamp the filter holder into the brew
group.
12
The brew group is ready for use.