Machine Set-up Guide
!
Fitting the Brush / Pad.
Note: Safety gloves are recommended for the changing of used brushes.
Brush Deck Pitch Adjustment
If the machine has a tendency to pull to either side while cleaning forwards,
this can be compensated for by turning the brush deck pitch adjustment knob.
Fitting the Floor Tool
The floor tool has been designed for quick fitting, allowing easy squeegee blade replacement and a safety knock-off feature if the
floor tool gets snagged, whilst in transit.
Fit the floor tool and retain using the
detent pin.
Push vacuum hose onto the floor tool;
ensure a tight fit.
NOTE: DO NOT push the vacuum hose
onto the floor tool with the floor tool in the
raised position.
Raise the floor tool for transit or
lower for cleaning operation using
the lifting handle fitted to the back
of the machine.
For fitting the floor tool blades (See P21).
ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF
BEFORE MAKING ANY ADJUSTMENTS
LH Bias: If the machine pulls to
the right, turn the knob clockwise
to apply left hand bias to the brush
deck.
RH Bias: If the machine pulls to the
left, turn the knob counter- clockwise
to apply right hand bias to the brush
deck.
2 x 370mm Brush or a 2 x 360mm Pad on the TGB
8572/200T. Featuring the Nulock brush system. The
brush is simply pushed and twisted to lock, making
fitting and removal a simple process.
Slide the brush / pad under the brush deck.
Fit the brush / pad onto the Nulock drive chuck,
twist to lock the brush / pad in place.
L
Turning the knob
clockwise will make the
machine pull more to
the left.
9
!
R
Turning the knob
counter-clockwise will
make the machine pull
more to the right