Liquefied gas connection (LPG)
Caution!
Observe the specific guidelines for each country.
If liquid gas (LPG) is used, the gas supply should be connected
via a gas hose or a fixed connector.
Important information on using a gas hose:
Use a safety gas hose or a plastic gas hose (8 or 10 mm in
■
diameter).
It must be attached to the gas connection using an approved
■
connecting device (e.g. a hose clamp).
The hose must be short and completely leak-tight. The hose
■
must not be longer than 1.5 m. Observe the applicable
guidelines.
The gas hose must be replaced once a year.
■
Place the new seal in the connection piece. Make sure the
1.
seal is seated correctly.
Conversion to a different gas type
Converting to a different gas type
The gas connection must be replaced.
■
The burner nozzles must be replaced.
■
Depending on the factory gas setting, the bypass screws in
■
the burner valves must either be replaced, or screwed in fully.
If present, the oven and grill nozzles must also be replaced.
■
Numbers are printed on the nozzles indicating their diameter.
Further information about the gas types suitable for the
appliance, as well as the corresponding gas nozzles, can be
found in the section entitled "Technical properties - gas".
After the conversion
After the appliance has been converted to a different gas
■
type, you must perform a leak test. See the section entitled
"Leak test".
After the appliance has been converted to a different gas
■
type, the correct flame formation must be tested. See the
section entitled "Correct flame formation".
Enter the newly-set type of gas and gas pressure in the table.
■
See the section entitled "Measures to be observed".
Caution!
After the appliance has been converted to a different gas type,
the labels giving information on the gas type and showing a
star must be affixed at the appropriate point on the rating plate
MAKE SURE THAT YOU DO THIS.
4
Secure the gas connection piece to the appliance using a 22
2.
mm spanner and place the connection piece into the
connection piece using a 24 mm spanner.
Fit the safety gas hose and use a pipe union or cable clamp
3.
to tighten it securely.
For information on how to carry out leak testing, see the
4.
section entitled "Leak testing". Open the gas connection shut-
off.
Note: Use a torque wrench to connect the appliance.
Functional parts for the gas conversion
The functional parts that are required for the gas conversion in
accordance with the instructions are displayed below.
You will find the correct nozzle diameters in the table in the
section entitled "Technical properties - gas".
Always use new seals.
The gas connecting piece to be used may vary depending on
the gas type and country-specific regulations.
(*) These functional parts must be used when the gas is
connected.
Bypass screw
Burner nozzle
(*) Seal