TECNICAL DATA
MODEL
air to water heat pump
with supplementary heater
Rated heat output
Annual energy consumption
Seasonal space heating energy effi ciency
Sound power level, outdoor
Sound power level, indoor (1 zona)
Declared capacity and coeffi cient of performance for heating at indoor conditions 20°C and outdoor temperature Tj
Climate
Bivalent temperature
Operating limit temperature
Heating water operation limit temperature
Tj = -7 °C
Tj = 2 °C
Tj = 7 °C
Tj = 12 °C
Tj = biv
Tj = Operating limit temperature
Degradation coeffi cient
Tj = -7 °C
Tj = 2 °C
Tj = 7 °C
Tj = 12 °C
Consumo energetico in modi diversi dal modo attivo
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Apparecchio di riscaldamento supplementare
Rated heat output (**)
Type of energy input
For heat pump combination heater
Declared load profi le
Daily electricity consumption
Annual electricity consumption
Water heating energy effi ciency
Other items
Capacity control
Outlet temperature capacity control
Water fl ow rate capacity control
Per pompe di calore aria/acqua
Rated Air fl ow rate, outdoor.
The water heat exchanger fouling factor is 0 (m
*
Standard Eurovent LCP/A/CHF conditions in heating mode: water heat exchanger entering/leaving water temperature 30 °C/35 °C, outside air temperature 7 °C db/6 °C wb.
Standard Eurovent LCP/A/CHF conditions in cooling mode: water heat exchanger entering/leaving water temperature 23 °C/18 °C, outside air temperature 35 °C.
**
Standard Eurovent LCP/A/AC conditions in heating mode: water heat exchanger entering/leaving water temperature 40 °C/45 °C, outside air temperature 7 °C db/6 °C wb.
Standard Eurovent LCP/A/AC conditions in cooling mode: water heat exchanger entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
*** Conditions in heating mode: entering/leaving water temperature 55 °C/a, outside air temperature 7 °C db/6 °C wb. Performances are in accordance with EN 14511.
**** Based on the following conditions: entering/leaving water temperature 35 °C/30 °C, outside air temperature 7 °C.
† Based on the following conditions: entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
Note: The sound pressure level is measured in a hemisperic fi eld at 4 m distance from the unit.
46 /
12 kW
[kW]
8,82
[%]
6387
[%]
111
[dB]
67
[dB]
[°C]
[°C]
[°C]
Capacità
[kW]
7,08
[kW]
4,53
[kW]
2,94
[kW]
2,57
[kW]
7,08
[kW]
6,73
[kW]
0
[kW]
0,084
[kW]
0,05
[kW]
0,05
[kW]
XL
10,341
2271
95
[m3/h]
6000
2
K)/W for all conditions.
15 kW
SI
SI
9,20
5928
125
68
48
Average
-7
-20
60
COPd
Capacità
COPd
Capacità
1,99
8,14
2,04
7,53
3,02
5,10
3,05
5,55
4,14
3,59
4,33
3,55
5,71
3,13
6,02
4,03
1,99
8,14
2,04
7,53
1,80
7,73
1,84
7,15
0,90
0
0,092
0,05
0,05
4
Electric
XXL
10,341
2271
95
Variable
Variable
Fixed
6200
12 T kW
15 T kW
8,51
9,52
5332
6043
128
127
68
68
COPd
Capacità
COPd
1,98
8,42
1,90
3,36
5,46
3,33
4,38
3,36
4,10
5,93
2,90
5,37
1,98
8,42
1,90
1,79
8,00
1,72
0
0
0,088
0,09
0,05
0,05
0,05
0,05
XXL
XXL
10,341
10,341
2271
2271
95
95
6000
6200