INTERNAL UNIT
Weights and dimensions
A
B
50
122
194
266
338
410
NIMBUS MGP
A. Hot/cold water fl ow from the external unit G 1" M
B. Cold/Hot water return to the external unit G 1" M
C. Hot/cold fl ow to the installation G 1" M
D. Cold/Hot water return from the installation G 1" M
NIMBUS MGP
1 ZONA
44 /
C
D
600
Kg
30
Overall view MGP 1 ZONE
5
4
6
7
8
9
10
11 12
1. Circulator
2. Temperature sensor (return from the installation)
heating/cooling
3. Discharge valve
4. Expansion vessel
5. Automatic air purge
6. Temperature sensor (fl ow to the installation) hea-
ting/cooling
7 Safety thermostat (automatic switch)
8. Safety thermostat (manual switch)
9. Heating back-up resistance
(2 kW + 2kW + 2kW)
10. Manometer
11. Pressure switch
12. Safety valve 3 bar
3
2
1