Download Inhoudsopgave Inhoud Print deze pagina

Removing The Insulation - Nibe VPB 500 Gebruikers- En Installatiehandleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Removing the insulation

The insulation can be removed to facilitate handling in
confined spaces. (The diameter without insulation is for
VPB 500 Ø668 mm, for VPB 750 Ø766 and for VPB 1000
Ø866 mm).
Lift off the plastic top and the top insulation.
On VPB 500, the lifting eye on the top must be un-
screwed first.
Remove the joining plates holding the insulated jacket
halves together. Do not use any tools when dismant-
ling.
Unhook and remove the insulated jacket halves, the
outer diameter of the heater becomes approx. 200
mm less without the insulated jackets.
The figure shows VPB 1000
with insulation
Carry out assembly in reverse order.
Install the enclosed insulation plugs around each connec-
tion. Finally, fit all the enclosed cover discs on each con-
nection by pressing them over the connections.
NOTE
Fit the cover discs and the insulation plugs be-
fore installing the pipe.
NOTE
In certain cases, more insulation plugs are en-
closed than are required.
VPB 500, 750, 1000 | GB
Do not use any tools when
dismantling the joining plate
Insulation removed
21

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

7501000

Inhoudsopgave