INTRODUCTION Thank you for purchasing a product. Read this manual and all other manuals pertaining to the Spray Star 1000 carefully as they have safety, operat- ing, assembly and maintenance instructions. Failure to do so could result in personal injury or equipment dam- age.
SYMBOLS Read Operator’s Electrical Power No Electrical Manual Power Engine - Stop Engine - Start Engine - Run Temperature Water Engine Oil Light Temperature Gasoline Diesel Glow Plug - On Glow Plug - Off Glow Plug Hour Meter Hour Meter Fuse Hand Throttle Choke - Closed...
Pagina 5
SYMBOLS Up/Down Arrow Down/Lower Up/Raise Manual No Smoking Moving Parts Operation Step Hot Surface Pinch Point Hydraulic Fluid Lift Arm Tractor Penetration Engage Disengage Ground Speed Fast Slow Forward High Warning Danger Reverse Neutral Caution...
Pagina 6
SAFE PRACTICES 1. It is your responsibility to read this manual and all publications associated with this machine. 2. Never allow anyone to operate or service the machine or its optional equipment without proper training and instructions. Never allow minors to operate any equipment. 3.
SAFE SPRAYING PRACTICES Persons engaged in the handling, preparation or application of chemicals must follow accepted practices to insure the safety of themselves and others, 1. WEAR protective clothing including: gloves, hat, respirator, eye protection and skin covering suitable for protection from chemicals being used.
SETUP The Spray Star 1000 arrives from setup and ready for service. Depending on freight conditions the tires, wheels, and steering wheel may have to be installed. The spray system is normally shipped attached to the 1000 Prime Mover. If a spray system is to be fitted to a Prime Mover by a dealer or owner, assemble and attach the components in accordance with the parts drawings in this manual.
SET UP (CONTINUED) 11. Machine should be greased before starting, refer to Spray Star 1000 Parts/Service Manual for location. 12. Attach the Spray Boom and any other Optional Equipment to the Prime Mover, in accordance with instructions in the Spray Star 1000 Parts/Service Manual. The nozzles must be the correct distance above the turf as described in Turf Spraying Guide.
Pagina 11
CONTROLS & INSTRUMENTS (CONTINUED) I. Spray Boss Control - Engages and disengages speed boss. Forward is engage and all the way back is disengage. When the lever is engaged it sets a stop for the accelerator. The accelerator pedal must be used to maintain this speed.
OPERATION Before operating the Spray Star 1000, become familiar with all controls and functions. Also complete all mainte- nance requirements and read all safety warnings. Knowing the Spray Star 1000 thoroughly, how it operates, and by doing the prescribed maintenance steps, you can expect trouble free operation for years to come. SAFETY Safety needs to always be the concern of an operator of a moving vehicle or any machine with moving parts.
Pagina 13
OPERATION (CONTINUED) Before using the Spray Star, the operator and spray technician must familiarize themselves with all of the information on chemical spraying contained in the Turf Spray Guide. All testing and calibrating of sprayers is to be done with water, not chemicals. This insures the safety to all involved in performing the calibration operation.
Pagina 14
OPERATION (CONTINUED) SPRAYER VALVE SETTINGS AND SPRAY TANK AGITATION The gate valve on the suction side of the pump, between the tank and the pump must be open before pump is engaged. Close this valve only when necessary to clean the filter with spray material in the spray tank. There are two manual flow control valves on the discharge side of the spray system.
CONSOLE FEATURES This Console (PGM F) requires selection of US (acres); SI (hectares) or TU (1,000 sq ft) area and SP1 (wheel drive, etc). A. POWER - Turns Console power OFF or ON. Turning Console OFF does not affect the data stored in the computer.
CONSOLE PROGRAMMING When entering data into the Console computer, the entry sequence is always the same. Data must be entered into the first eight keys. 1. Depress the key which you wish to enter data. 2. Depress the “Enter” key. An “E” will illuminate in the DATA display.
CONSOLE CALIBRATION (CONTINUED) 6. Recheck the new Speed Cal numbers. Zero out Distance display as in step 3. Enter the new Speed Cal number as in step 1. Repeat steps 4 and 5. MEASURE CAREFULLY. Be sure tire is properly inflated before measuring. Measure tire in type of soil in which you will be spraying.
INITIAL PROGRAMMING OF CONSOLE COMPUTER When you first turn on Console power, after all installation procedures have been completed, the Console will flash “CAL” in the RATE display and “US” in the DATA display. This means you must “calibrate” or program the Console before it can be operated.
Pagina 19
INITIAL PROGRAMMING OF CONSOLE COMPUTER (CONTINUED) 8. Enter SPEED CAL of 688 in key labeled: 9. Enter METER CAL calibration number in key labeled: 10. Enter VALVE CAL calibration number (2123) in key labeled: 11. Enter the target RATE 1 (GPA) (lit/ha) (GPK) you want to spray in the key labeled: 12.
Pagina 20
INITIAL PROGRAMMING OF CONSOLE COMPUTER (CONTINUED) 6. To display SPEED, momentarily depress the key labeled: 7. To display VOL/MIN., momentarily depress the key labeled: 8. To display AREA/HOUR, momentarily depress key labeled: This is an actual calculation of AREA/ HOUR at the present speed you are going. It is not an average over time. 9.
Pagina 21
INITIAL PROGRAMMING OF CONSOLE COMPUTER (CONTINUED) ENTER MODE SEQUENCE WITH ACTIVATED DATA-LOCK 1. Depress the key into which you wish to enter data. 2. Depress CODE message will appear. Enter your DATA-LOCK CODE. If code is correct, “E” will appear. Now enter data normally. The DATA-LOCK feature prohibits the entry of data without first entering the DATA-LOCK CODE.
INITIAL PROGRAMMING OF CONSOLE COMPUTER (CONTINUED) LOW LIMIT FLOW SET POINT AND LOW LIMIT ALARM Depress until DATA display flashes. A low limit flow rate may now be entered. If actual volume Per minute falls below this limit, the Control Valve stops closing, the Alarm sounds and the rate display flashes “LL”.
SPRAY OPERATION (After Proper Setup and Calibration) 1. Add the amount of water required for the spray operation to tank using air gap filler. 2. Start engine, set engine speed below 2000 RPM, and engage pump after taking all previously described safety and operation precautions.
Pagina 24
SPRAY OPERATION (CONTINUED) One of the most common causes for faulty-pump performance is corrosion inside the pump. Flush the pump and entire system with a solution that will chemically neutralize the liquid pumped. Mix according to manufacturer’s directions. This will dissolve most residue remaining in the pump, leaving the inside of the pump clean for the next use.
This section is intended to offer practical guidelines for the distribution of liquid chemicals over an area of turfgrass such as golf courses, park land, school grounds and lawns. SMITHCO makes no representation as to the suitability of any technique or product for any particular situation. This section is suitable for self-propelled spray vehicles or sprayers mounted onto vehicles.
HOSE & HANDGUN SPRAYING A handgun (hand-nozzle or hand-lance) is used to control and direct the spray pattern to the ground, shrub or tree. They must be constructed of long lasting and noncorrosive materials such as brass, stainless or aluminum. The handgun fits to a hose of any length from the sprayer allowing operator mobility.
NOZZLES ( CONTINUED) 3. Disperse the material in a specific pattern that will insure even distribution of chemical across the swath covered by the boom. As shown (to the right) the pattern formed by flat fan (TeeJet) nozzles would show most liquid concentrated at the center, then tapering off where it begins to overlap with the next nozzle-approxi- mately...
CALIBRATION INTRODUCTION Calibrating simply means to adjust a set of variables on the sprayer in order to deliver the desired amount of chemical to a known area of turf. The job of calibrating the sprayer consists of balancing these variables so that your sprayer delivers the desired application rate.
THE NOZZLE CHART METHOD OF CALIBRATION The Nozzle Chart Method is useful when the sprayer nozzles are new or nearly new. It is also the most useful method to employ when the sprayer is equipped with an Electronic Spray Control System. The Electronic Spray Control System does most of the calibration work, it is up to the operator to select the proper combination of nozzle size and ground speed which will deliver the desired application rate.
THE NOZZLE CHART METHOD OF CALIBRATION (CONTINUED) 5. For Sprayer with Electronic Spray Control Systems. On sprayers equipped with Electronic Spray Control Systems such as those manufactured by Raven Ind., Micro-Trak Co. and Dickey-John Co., it is still important to select the right type and size of nozzle for the required operation.
Pagina 32
THE “128” METHOD OF BOOM SPRAYER CALIBRATION The carrying or towing vehicle is to be traveling at the desired speed when it crosses the start line of the measured course. Repeat this procedure and determine the average of the two times. 3.
ABBREVIATIONS AND CONVERSIONS Gallons per minute Centimeters lit/min Liters per minute Decimeters dl/min Deciliter per minute Meter Pounds per square inch Millimeters Kilometers Miles per hour Gallon per acre km/h Kilometers per hour lit/ha Liters per hectare Volume per ACRE ml/ha Milliliter per hectare Volume per Hectare...
EC DECLARATION OF CONFORMITY according to Directive 89/392/EEC SMITHCO INC. (Name of supplier) 34 West Ave. Wayne, PA 19087 USA (Full address of the manufacture - authorized representative established in the Community must also give the business name and address of the manufacture)
Batteries. Wheels and tires. A copy of the warranty for the above items is furnished if necessary with each SMITHCO product. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
Links en rechts zijn gezien vanaf de bestuurdersstoel met het gezicht naar voren. Alle Smithco-machines hebben een Serienummer en Modelnummer. Beide nummers zijn nodig bij het bestellen van onderdelen. Het serienummerplaatje op de Spray Star 1000 bevindt zich op het rechter hoofdframe, vóór de olietank.
VEILIGHEID Lees deze handleiding en alle veiligheidssymbolen door en begrijp ze alvorens de machine te bedienen en te onderhouden. Lees elk jaar de veiligheidsinstructies en –voorschriften. OPMERKING! DIT VEILIGHEIDSSYMBOOL KUNT U DOOR DE GEHELE HANDLEIDING VINDEN EN WORDT GEBRUIKT OM UW AANDACHT TE VESTIGEN OP INSTRUCTIES DIE UW PERSOONLIJKE VEILIGHEID EN DE VEILIGHEID VAN ANDEREN BETREFFEN.
18. Nooit passagiers vervoeren. 19. Stop de motor voordat u reparaties/afstellingen maakt of de olie controleert/toevoegt aan het carter. 20. Gebruik onderdelen en materialen die alleen door Smithco zijn geleverd. Pas onderdelen of functies niet aan. 21. Sand Star 48V: Gebruik geïsoleerde steeksleutels en laat de steeksleutels niet in contact komen met metalen delen van het voertuig.
Veilige sproeivoorschriften Personen die betrokken zijn bij de hantering, voorbereiding of toepassing van chemicaliën moeten de aangenomen voorschriften opvolgen om de veiligheid van henzelf en anderen te garanderen. DRAAG beschermende kleding waaronder: handschoenen, hoofddeksel, mondkapje, oogbescherming en huidbedekking die geschikt is om te beschermen tegen de gebruikte chemicaliën. WAS u grondig na elke blootstelling aan chemicaliën, waarbij u extra let op ogen, neus, oren en mond.
Specificaties GEWICHT EN AFMETINGEN Lengte 285 cm Breedte 178 cm Breedte met geopende giek 457 cm Hoogte 122 cm Wielbasis 135 cm Gewicht leeg 544 kg Gewicht vol 998 kg GELUIDSNIVEAU (DB) Op oorhoogte 88 dB Op 0,914 m afstand 84 dB Op 9,14 m afstand 72 dB...
SETUP De Spray Star 1000 is in de fabriek van Smithco ingesteld en klaar voor gebruik. Afhankelijk van de vrachtomstandigheden moet de accu nog worden geïnstalleerd. Het sproeisysteem wordt normaliter verscheept als accessoire bij de 1000 Prime Mover. Als een...
REGELINGEN EN INSTRUMENTARIA A. Urenteller - De urenteller geeft de bedrijfsuren van de machine aan. Deze werkt alleen als de contactschakelaar is ingeschakeld. Snelheidsmeter – De snelheidsmeter geeft de grondsnelheid van het voertuig in mijl per uur en kilometer per uur aan. C.
Pagina 52
REGELINGEN EN INSTRUMENTARIA N. Sproeinaafregeling – Schakelt de snelheidsnaaf in en uit. Vooruit is inschakelen en helemaal terugtrekken is uitschakelen. Wanneer de hendel is ingeschakelt, stelt deze een stop in voor de versnelling. Het snelheidspedaal moet gebruikt worden om deze snelheid te handhaven. Om de snelheid af te stellen gebruikt u de knop aan het uiteinde van de hendel: linksom verhoogt de snelheid, rechtsom verlaagt de snelheid.
BEDIENING Zorg dat u bekend raakt met alle regelingen en functies alvorens de Spray Star 1750 te bedienen. Voer alle onderhoudsinstructies uit en lees alle veiligheidswaarschuwingen. Door de Spray Star 1750 grondig te leren kennen, hoe de machine werkt en door de voorgeschreven onderhoudsstappen uit te voeren, kunt u een probleemloze werking gedurende vele jaren verwachten.
Pagina 54
BEDIENING De bediener en de sproeitechnicus moeten zich eerst alle informatie over chemische sproeiwerkzaamheden, opgenomen in de eigen maken, alvorens de Spray Star te gebruiken. Handleiding voor het besproeien van gras Alle tests en kalibreringen van de sproeiers worden met water en niet met chemicaliën uitgevoerd. Dit garandeert de veiligheid van alle betrokkenen bij het uitvoeren van de kalibreringswerkzaamheden.
FUNCTIES BEDIENINGSPANEEL Op dit bedieningspaneel (PGM F) moeten oppervlakte-eenheden US (acres); SI (hectare) of TU (1000 sq ft) en SP1 (wielaandrijving enz.) ingesteld worden. A. POWER (vermogen) – Hiermee schakelt u het vermogen van het bedieningspaneel OFF (uit) of ON (aan).
PROGRAMMEREN BEDIENINGSPANEEL Bij het invoeren van gegevens in de computer van het bedieningspaneel is de invoerprocedure altijd dezelfde. Gegevens moeten ingevoerd worden met de eerste acht toetsen. 1. Druk op de toets waaraan u gegevens wilt toevoegen. 2. Druk op de toets Enter. Een “E” gaat aan op het scherm DATA (gegevens).
Pagina 57
KALIBREREN BEDIENINGSPANEEL Controleer opnieuw de nieuwe cijfers bij de snelheidskalibrering. Voer stap 3 uit om het scherm Distance (Afstand) leeg te maken. Voer het nieuwe getal voor de snelheidskalibrering in zoals in stap 1. Herhaal stappen 4 en 5. MEET ZORGVULDIG. Zorg ervoor dat de banden goed zijn opgepompt alvorens te meten. Meet de banden op het type grond waarop u gaat sproeien.
EERSTE KEER PROGRAMMEREN VAN DE COMPUTER Als u voor de eerste keer het bedieningspaneel inschakelt nadat alle installatieprocedures zijn voltooid, knippert 'CAL' (kalibrering) op het scherm RATE (snelheid) en ‘US’ op het scherm DATA (gegevens). Dit betekent dat u het bedieningspaneel moet ‘kalibreren’...
Pagina 59
EERSTE KEER PROGRAMMEREN VAN DE COMPUTER 8. Voer 688 in voor de snelheidskalibrering onder de toets met opdruk: 9. Voer het kalibreringscijfer voor METER CAL (kalibrering van de meters) in onder de toets met opdruk: 10. Voer het kalibreringscijfer voor VALVE CAL (kalibrering klep) (2123) in onder de toets met opdruk: 11.
Pagina 60
EERSTE KEER PROGRAMMEREN VAN DE COMPUTER 6. Om SPEED (snelheid) weer te geven, drukt u één keer op de toets met opdruk: 7. Om VOL/MIN (volume/minuut) weer te geven, drukt u één keer op de toets met opdruk: 8. Om AREA/HOUR (oppervlak/uur) weer te geven, drukt u één keer op de toets met opdruk: geeft een werkelijke berekening van oppervlak/uur weer bij de huidige snelheid.
Pagina 61
EERSTE KEER PROGRAMMEREN VAN DE COMPUTER PROCEDURE VOOR HET INSTELMODUS MET GEACTIVEERDE DATA-LOCK 1. Druk op de toets waaraan u gegevens wilt toevoegen. 2. Druk op de toets . Het bericht CODE verschijnt. Voer de DATA-LOCK CODE (gegevensblokkeringscode) in. Als de code juist is, verschijnt er een “E”. U kunt nu zoals gebruikelijk gegevens invoeren.
EERSTE KEER PROGRAMMEREN VAN DE COMPUTER INSTELPUNT ONDERGRENS STROOMSNELHEID EN GRENSALARM Druk op de toets totdat het scherm DATA (gegevens) knippert. U kunt nu een ondergrens invoeren voor de stroomsnelheid. Als het werkelijke volume per minuut onder deze grens komt, gaat de regelklep open en klinkt het alarm. Op het scherm RATE (snelheid) knippert “LL”...
Afkortingen en omrekeningen gal/min Amerikaanse gallon per minuut centimeter lit/min liter per minuut decimeter dl/min deciliter per minuut meter Pounds per vierkante inch millimeter kilometer mijl per uur gal/acr Amerikaanse gallon per acre km/u kilometer per uur lit/ha liter per hectare volume per acre ml/ha milliliters per hectare...
Pagina 70
Conformidad de la CE • Declaração de Conformidade da CE We the undersigned • Nous, soussignés • Wij, ondergetekenden • Wir, die Unterzeichnenden • Noi sottoscritti Undertegnede • Undertecknarna • Me allekirjoittaneet • Los abajo firmantes • Nós, abaixo assinados Smithco Inc. 34 West Avenue Wayne, PA 19087-3311 Declare that the machine Described Below •...
Pagina 71
Bevoegde Productendistributeur van Smithco van wie u het Product heeft gekocht, zodra u denkt dat een garantieconditie bestaat. Indien u hulp nodig hebt bij het localiseren van een Bevoegde Distributeur van Smithco, of als u vragen hebt betreffende uw garantierechten of –verantwoordelijkheden, kunt u contact met ons opnemen: Smithco Product Support Department Highway SS @ Poplar St.
Pagina 72
Sommige landen/staten staan de uitsluiting van indirecte, inherente of vervolgschade niet toe, dus de bovenstaande uitsluiting hoeft geen betrekking te hebben op u. Smithco neemt op zich noch bevoegt enig persoon op zicht te nemen in diens plaats, andere aansprakelijkheid in verband met de verkoop of gebruik van dit product.