6/ USING YOUR WINE CABINET FOR THE FIRST TIME
III-A. Description
(multi-temperatures S-4000-L)
A
B
C
D
E
B
Nv
M
L
K
A
Lighting mode
B
Temperature zones concerned
C
Sensor fault alarm
D
Temperature alarm
E
Charcoal filter alarm
F
Confirmation and setting access key
G
Setting and selection keys
III-B. Temperature setting
Recommended temperature setting range for the low temperature: 7 - 9 °C / 45 - 48 °F.
Recommended temperature setting range for the high temperature: 17 - 19 °C / 63- 66 °F.
2 sec.
5 sec.
Press and hold down the
key for 3 secs to power up.
1
Press and hold down the
key for approximately 2 secs.
The display will start to flash.
2
Press the
or
keys to set the desired temperature.
3
Press the
button to confirm. The right-hand display will flash.
The value shown on the display is the actual temperature inside
the cabinet. It is therefore necessary to wait before your new
setting takes effect.
28
GB
F
G
H
The tactile keys are very sensitive.
There is no need to apply force, a light
touch is sufficient to register the
command. Remember to remove your
finger from the panel between presses.
J
I
H
Lighting mode access and confirmation key
I
Charcoal filter meter access key
J
ON /OFF key
K
High temperature in cabinet display
L
Hot circuit indicator
M
Cold circuit indicator
N
Low temperature in cabinet display
4
Press the
or
keys to set the desired temperature.
5
Press the
button to confirm.
• For the low temperature, the default setting is 8 °C / 46 °F. However you
can set the temperature between 5 - 10 °C / 41 - 50 °F.
• For the high temperature, the default setting is 18 °C / 64 °F.
• However you can set the temperature between 15 - 20 °C / 59 - 68 °F.
N.B: in order to operate correctly, your cabinet must be placed in a room
with a temperature of 12-30 °C / 54-86 °F.
6/ USING YOUR WINE CABINET FOR THE FIRST TIME
IV. Relative humidity level display
Your wine cabinet has a function for measuring humidity levels, allowing
you to see the level of relative humidity inside the appliance, when the
setting is 9 - 15 °C.
The ideal level of humidity is above 50 % and ideally between 60 and 75 %.
To display the humidity level inside your cabinet, press and
hold down the
button for 2 seconds.
V. Setting the lighting mode
1
Press 2 seconsd the
key. The indicator of the active mode will flash
There are 2 setting options for lighting:
Permanent lighting (mood lighting for a cabinet fitted with a glass
door, for example).
Lighting disabled
VI. Charcoal filter meter display
When using the filter for the first time or replacing it, set the meter to 365.
1
Press 2 seconds the
key.
The display will flash.
2
Press the
key to set to 365.
(1-temperature model only)
If you want to increase the level of relative humidity in your cabinet, pour
the equivalent of one glass of water on the humidity cartridge located on
the bottom of the cabinet. You need to remove your bottles before.
2sec
2sec
2
Press the
or
keys to select the desired mode.
3
Press the
key to confirm.
Precaution: bright light, never look directly at the LED
beam.
2sec
3
Press the
to confirm
The alarm display will switch off
You can consult the meter by pressing the
key.
29
GB