Download Inhoudsopgave Inhoud Print deze pagina

VOLTCRAFT VC175 Gebruiksaanwijzing pagina 4

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Do not exceed the maximum permitted input values. Do not contact circuits
or parts of circuits if there could be voltages higher than 25 V ACrms or 35 V
DC present within them. Mortal danger!
Before measuring, check the connected measuring lines for damage such as,
for example, cuts, cracks or squeezing. Defective measuring cables must no
longer be used. Mortal danger!
During measuring, do not grip beyond the tangible grip range markings
present on the test prods.
You may only connect the two measuring leads to the measuring device
that are required for measuring operation. Remove all measuring leads not
required from the device for safety reasons.
d) Voltage measuring "V"
Before measuring voltages, always make sure that the measuring instrument is not
set to a measuring range for current.
e) Current measuring "A"
• The voltage in the measuring circuit may not exceed 250 V.
• Measuring operations of >5 A may only be performed for at most 10 seconds with
a subsequent measuring pause of 15 minutes.
• All current measuring ranges are provided with fuses and thus protected against
overload.
f) Resistance measuring
Make sure that all the circuit parts, switches and components and other objects of
measurement are disconnected from the voltage and discharged.
g) Diode test
Make sure that all the circuit parts, switches and components and other objects of
measurement are disconnected from the voltage and discharged.
h) Non contact voltage test "NCV"
• Make sure that all measuring sockets are unoccupied. Please remove all
measuring leads and adapters from the measuring device.
• This function only serves as aid. Prior to performing work on these cables,
you have to perform contact measuring operations to check for the absence of
voltage.
i) Maintenance and cleaning
• Never operate the measurement device when it is open. RISK OF FATAL
INJURY!!
• Regularly check the technical safety of the instrument and measuring lines, e.g.
check for damage to the housing or squeezing etc.
j) Cleaning
• Live components may be exposed if covers are opened or parts are removed.
• The connected lines must be disconnected from the measuring device and all
measuring objects prior to cleaning or repairing the device. Switch the DMM off.
• Do not use any carbon-containing cleaning agents or petrol, alcohol or the like to
clean the product.
• These could corrode the surface of the measuring instrument. Furthermore, the
fumes are hazardous to your health and explosive. Moreover, you should not use
sharp-edged tools, screwdrivers or metal brushes or similar for cleaning.
• For cleaning the device or the display and the measuring lines, use a clean,
fuzz-free, antistatic slightly damp cloth.
k) Fuse replacement
• Using mended fuses or bridging the fuse holder is not admissible for safety
reasons.
• Never operate the measurement device when it is open. RISK OF FATAL
INJURY!
l) Inserting/replacing the battery
• Do not leave flat batteries in the device. Even batteries protected against leaking
can corrode and thus release chemicals which may be detrimental to your health
or destroy the battery compartment.
• Do not leave batteries lying around carelessly. They might be swallowed by
children or pets. If swallowed, consult a doctor immediately.
• If the device is not used for longer periods of time, remove the batteries in order
to prevent leaking.
• Leaking or damaged batteries might cause acid burns when getting into contact
with skin. Therefore, use suitable protective gloves.
• Make sure that the batteries are not short-circuited. Do not throw batteries
into fire!
• Batteries may not be recharged. Danger of explosion!
m) Troubleshooting
Repairs other than those described should only be carried out by an authorised
specialist.
Legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the
time of printing.
© Copyright 2015 by Conrad Electronic SE
V1_1115_02_DS

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

124457

Inhoudsopgave