INTENDED USE
- Measuring and displaying electric parameters in the range of excess voltage category
III (up to max. 600 V against ground potential, pursuant to EN 61010-1) and all lower
categories.
- Measuring direct and alternating voltage up to a maximum of 600 V
- Measurement of direct and alternating current up to 10 A
- Measuring of resistance up to 40 MΩ
- Acoustic continuity check
- Diode test
- Non-contact 230 V/AC voltage test
- Electric current measurement
The two measuring inputs are secured against overload. The voltage in the measuring circuit
may not exceed 600 V. The measuring ranges are equipped with ceramic high-performance
fuses.
The device may only be operated with a 9 V block battery.
The measuring instrument must not be operated when it is open, i.e. with an open battery
compartment or when the battery compartment cover is missing. Measuring in damp rooms or
under unfavourable ambient conditions is not admissible.
For safety reasons, when measuring only use measuring cables or accessories which are
adjusted to the specifications of the multimeter.
Unfavourable ambient conditions are:
• Wetness or high air humidity,
• Dust and flammable gases, vapours or solvent,
• Thunderstorms or similar conditions such as strong electrostatic fields etc.
Unauthorised conversion and/or modification of the device are inadmissible because of safety
and approval reasons (CE). Any usage other than described above is not permitted and can
damage the product and lead to associated risks such as short-circuit, fire, electric shock, etc.
Please read the operating instructions thoroughly and keep them for further reference.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
Observe all safety instructions and information within the operating manual.
SYMBOL EXPLANATION
VERSION 11/15
CAT II
CAT III
SAFETY INSTRUCTIONS
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in the manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
a) Persons / Product
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts,
highhumidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protectit from any accidental use. Safe operation can no longer be guaranteed if
the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
candamage the product.
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
b) Batteries / Rechargeable batteries
• Correct polarity must be observed while inserting the batteries.
• Batteries should be removed from the device if it is not used for a long period of
time to avoid damage through leaking. Leaking or damaged batteries might cause
acid burns when in contact with skin, therefore use suitable protective gloves to
handle corrupted batteries.
• Batteries must be kept out of reach of children. Do not leave the battery lying
around, as there is risk, that children or pets swallow it.
• Batteries must not be dismantled, short-circuited or thrown into fire. Never
recharge non-rechargeable batteries. There is a risk of explosion!
c) Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
An exclamation mark in a triangle indicates important instructions in the
operating manual which absolutely have to be observed.
The triangle containing a lightning symbol warns of danger of an electric
shock or of the impairment of the electrical safety of the device.
This product has been CE-tested and meets the necessary European
guidelines.
Class 2 insulation (double or reinforced insulation)
Overvoltage category II for measurements on electric and electronic
devices connected to the mains supply with a power plug. This category
also covers all smaller categories (e.g. CAT I for measuring signal and
control voltages).
Overvoltage category III for measuring in building installation (e.g. outlets
or subdistribution).This category also covers all smaller categories
(e.g. CAT II for measuring electronic devices).
Ground potential