CONNECTION OF A MODEL OVER A SINK
*Mandatory pressure reducer if the water pressure in your house is greater than 5 bar (0.5 MPa). It
must be installed at the meter outlet.
2 - free flowing, to supply a single water point: this type of installation is specially adapted to small-
capacity water heaters (10, 15 and 30 l) installed over sinks when they cannot be installed under
pressure. The installation should include a specific mixer tap. In this case, a safety unit is not
required.
Dripping from the tap is normal during heating periods.
Do not obstruct the flow.
IMPORTANT: if your plumbing is not made of copper (PER, multi-
layer, etc.), a copper pipe must be installed with a minimum length
of 50 cm (DTU 60.1) and/or a temperature limiter at the hot water
outlet of your water heater.
Filling the water heater:
a.
Open the hot water taps in the building.
b.
Open the cold water inlet valve on the safety unit.
c.
The water heater will be filled when you notice cold water flowing from the hot water taps.
Close the hot water taps.
d.
Make sure that the safety unit is operating correctly by using the drain valve.
A little water should flow out.
e.
Check the seal on the water heater's water outlets and inlets.
If you notice a leak, attempt to tighten the connectors.
If the leak persists, drain the water heater and refit the connectors.
Repeat the operation to create a perfect seal.
8
FIG.4.
1-Cold water inlet
2-Pressure reducer (if present)*
3-Safety unit (mandatory)
4-Syphon
5-Dielectric joint
(mandatory and supplied)
6-Hot water outlet
%CONNECTION OF A MODEL UNDER A SINK
FIG.5.