OPERATION
By default the fan is set in automatic mode, so the fan speed is regulated
automatically following the cooking zone with the highest power currently active.
Switching on the manual mode
With the hob switched on, select a power level on the hood slider to switch from
automatic to manual mode. The symbol
Notes
An increasing of cooking zones power will cause an automatic increase of fan
speed.
A decreasing of cooking zones power will cause an automatic decrease of fan
speed.
The actual steam generation is delayed. When changing the cooking level, the
automatic fan level follows generally after 20 sec delay
Switching back to automatic mode
Press below the symbol
fully brightened.
The system has a follow-up / after-run function, which should ensure that any
existing odours and steam can be extracted.
After completing the cooking process and switching off the hob, the fan continues to
run.
There is an automatic after-run of 5 minutes on level 1.
Notes
The fan speed can also be changed in the after-run. After-run ends immediately if 0
is selected.
There is the possibility to set a fan timer analogue to the cooking zone timer. The
timer is displayed on the timer display. The fan timer does not start to run until the
cooking process has finished.
The following situations can occur:
Manual mode - situation 1
Fan level set, timer set, all cooking zones switched off.
Cooktop remains on; fan level remains active for timer time.
The cooktop switches off completely.
Manual mode – situation 2
Fan level set, timer set; cooktop switched off via power button.
After-run level 1 is set and remains active for the timer setting time.
The cooktop switches off completely.
Automatic mode
Timer can be set as soon as the fan is running and starts to run as soon as all
cooking zones are off. A timer alarm after expiry of the after-run time does not
occur.
The pause symbol
also appears on the fan display when the pause is active. The
fan level (if greater than 0) is reduced to level 1. After the pause the previously set
level returns. For recall applies the same rule as for cooking zones. The fan level is
maintained and restored on recall.
The hood touch control includes a filter timer that reminds that is important to clean
the hood's grease filter on a regular basis (every 50 hours).
The filter run time is always counted when the fan is running, even during after-run.
After the time has elapsed the symbol
15
is now dimmed.
to return to automatic mode. The symbol
on the hood touch control lights up.
is now