Download Print deze pagina

SimPark Easymatic Installatiehandleiding pagina 24

Caravan mover

Advertenties

Beschikbare talen

Beschikbare talen

NL UK
Switch on the ECU
Without remote controller
After turning on the battery power, the ECU will be activated and 1 beep will be audible. If the remote controller
has not been recognized, the ECU will turn into sleeping mode. Power consumption in standby mode will be 90mA.
With controller
When the remote controller has been recognized, the ECU will be activated.The ECU will test the Relay and Fets
by switching the relay on and off.After 1 beep the cool fan's will be activated.Power consumption will be 330mA.
When the remote controller has been switched off, the ECU will enter automatically into the standby mode.
Safety features of the ECU
Switching off the remote controller
When you switch off the remote controller the ECU will enter automatically into standby mode.
The remote controller will automatically shut off after a time out of 60 seconds.
Temperature protection
The ECU will enter the error mode when the PC board has reached a temperature of +/- 75 degrees. See also
the summary of errors.The ECU will reset automatically when the temperature drops with 15 degrees.
Low voltage protection
The ECU will enter the error mode when the voltage drops under 8,5Volt. See error summary.
After 30 seconds the ECU will reset in case the voltage becomes higher than 8,5 volt.
Status legend
Status
Activation of ECU
Recognizing of remote controller
Tow hook detection
Switch next to antenna for resetting
the remote controller
Error
Maximum current level per motor.
Immediately disconnected @ +- 210A.
After 2 sec. disconnected @ 150A
Motor (detection) error
"Fets" error
Temperature above 75 degrees
Battery voltage lower than 8,5V
Number of beeps
1 x
1 x
1 per second
2 x
Beep salvo 3 seconds long per motor
Number of beeps per 2 seconds
3 x
4 x
5 x
6 x
24
Cooling fan
Off
On
Off
--