Download Print deze pagina

SimPark Easymatic Installatiehandleiding pagina 22

Caravan mover

Advertenties

Beschikbare talen

Beschikbare talen

NL UK
Rear view receiver
fig. 14
Match button for
remote controller
Top view receiver
fig. 15
Antenna connections (see fig. 15)
Pin 1
GND
Not in use, only in case of mounting a Coax centre antenna cable
Pin 2
Signal
Antenna : black supplied copper wire / flying lead or enter of a Coax cable
Pin 3
GND
Not in use, only in case of mounting a Coax cable protection shield
Pin connections (see fig. 15)
Pin 4
12 volt
+12 V External Buzzer, max. 500mA, is functional parallel to internal buzzer
Pin 5
GND
Brown cable to pin 13 of the towhook socket
Pin 6
12 volt
Purple cable to pin 9 of the towhook socket (safety feature)
Pin 7
Impuls
Green cable to engage the drive rollers off the tires
Pin 8
12 volt
Red cable to 12 volt + of battery use of a 10 Amp. fuse is advisable
Pin 9
Impuls
Yellow cable to disengage the drive rollers on the tires
Antenna:
Pin no.2 is the antenna
Pinnumber
9 8 7 6 5 4
Motor L
Battery
-
+
-
Multi connector: Pin 6 = 12 volt
Safety feature function
(pin 9 of tow hook socket)
Pinnumber
3 2 1
ECU
Motor R
+
-
22
+