ground and the walls of the room in which
the appliance is built.
• Bleed the gas pipe.
• Place the receiver; for details, see section 7.1 of the
Installation manual.
• Set the communication code between the remote control
and the receiver; see section 7.2 of the installation manual.
Caution
Do not ignite the appliance until it is fully
installed.
• Check the connections for gastightness as described in
section 8.1 of the installation manual.
• Check the line-pressure as described in section 8.2 of the
installation manual.
• Place the burner mounting plate plus accessories back and
fi x it with the self-tapping screws.
• When placing, slide the bottom strip in the U shaped not-
ches to the left and right; see Fig. 4g.
• Place the combustion chamber back in the convection box
and fi x it at both sides with the Allen screws.
Caution
- Properly connect the fl ue spigot to the
draft diverter when placing back the com-
bustion chamber; see Fig. 4f;
• Place the vermiculite tray in the rear of the combustion
chamber.
• Place the wood set; see section 6.7
• Remove the tape on the convection box.
6.5

Flue gas discharge system

For connection to an existing chimney – only allowed in
Great-Britain – the instructions from the separate booklet
'Fitting into a conventional class 1 chimney' also apply. In
addition to the installation instructions, this booklet also
contains supplementary tests.
6.5.1 General
The appliance is of the B
11AS
The passage to the outside is made with a roof terminal
(see section 6.5.2).
Caution
Use a suitable Ø100 mm diameter fl ue
gas discharge system provided with the
CE mark.
The fl ue gas discharge system is constructed from (the fl ue
spigot of) the appliance.
6.5.2
Connecting the fl ue gas discharge system
A discharge pipe of at least 3 metres, should be connected
to the appliance.
Bends in the fl ue gas discharge system are not allowed.
The roof terminal can end in a sloping and a fl at roof.
type.
The roof terminal can be supplied with an adhesive plate
for a fl at roof or with a universally adjustable tile for a
sloping roof.
Caution
- Maintain a distance of at least 50 mm
between the outside of the fl ue gas
discharge system and the walls and/or
the ceiling. If the system is built in (for
instance) a cove, it should be made with
non combustible material all around it;
- Use heat-resistant insulation material
when passing through combustible
material.
!Caution
Some heat-resistant insulation materials
contain volatile components that will
spread an unpleasant smell for a prolonged
time; these are not suitable.
Place the fl ue gas discharge system as follows:
• Build the system up from (the fl ue spigot of) the
appliance.
• Connect the pipe pieces.
• Apply suffi cient clamps, so that the weight of the pipes
does not rest on the appliance.
• Determine the remaining length of the roof terminal.
• Make sure the roof terminal has the right dimensions.
!Caution
Make sure that the right insertion length is
maintained.
• Connect the roof terminal to the discharge pipes.
!Caution
- Make sure that the universal tile fi ts well
with the surrounding tiles;
- Make sure that the adhesive plate fi ts well
onto the fl at roof.
6.6

Placing the chimney breast

This paragraph describes how the appliance should be built
in a chimney breast.
In order to provide proper heat discharge, there should be
suffi cient space around the appliance.
The chimney breast should be ventilated suffi ciently by
means of ventilation holes.
Caution
- Use non combustible and heat-resistant
materials for the chimney breast, inclu-
ding the top of the chimney breast, the
material in the chimney breast and the
back wall of the chimney breast;
- Make sure that the appliance is not car-
rying the weight of the chimney breast
when using stone-like materials;
- The ventilation holes – which should be
mounted as high as possible – should have
a combined passage of at least 200 cm
27