3.3 Precautions / safety instructions during

installation

Carefully observe the following precautions/safety

regulations:

• you should only install and maintain the appliance if you
are a competent installer in the field of atmospheric
gas-fired heating;
• do not make any changes to the appliance;
• use non combustible and heat-resistant materials for the
chimney breast, including the top of the chimney breast,
the material in the chimney breast and the back wall
against which the appliance will be placed;
• take sufficient measures to prevent temperatures of a wall
behind the chimney breast becoming too high, including
the materials and/or objects behind the wall;
• comply with the minimum required internal measure-
ments of the chimney breast;
• ventilate the chimney breast by means of the ventilation
holes, which will form a combined passage of at least
2
200 cm
;
• use a suitable flue gas discharge system that is provided
with the CE mark;
• maintain a minimum distance of 10 mm between the
appliance and the back wall;
• place the appliance on supports made of non combustible
and heat-resistant material;
• do not cover the appliance and/or do not wrap it in an
insulation blanket or any other material;
• make sure that combustible objects and/or materials have
a distance from the appliance of at least 500 mm;
• only ever use the supplied wood set;
• place the wood set exactly as described;
• make sure the pilot burner and the space around it is kept
free;
• make sure there is no dirt in gas pipes and connections;
• mount a gas tap directly next to the appliance;
• check the connections for gastightness before using the
appliance;
• replace a torn or broken glass pane;
• In case of a broken or torn glass pane, do not use the ap-
pliance and close the gas tap.
• remove the tape on the convection box, before you ignite
the appliance;
• do not ignite the appliance until it is fully installed.

3.4 Oxypilot safety

The appliance is provided with an oxypilot safety, which
will be activated if insufficient combustion air (oxygen) is
supplied.
If the oxypilot safety senses insufficient oxygen, the pilot
burner is switched off and the gas supply to the burner is
closed.
If the supply of combustion air is sufficient again, the
appliance can be restarted.
The supply of fresh air can be controlled by installing/
opening ventilation holes.
! Caution
In case of a house with a mechanic exhaust
system and/or an open kitchen with
cooker hood, a permanent ventilation
opening is required in the area surrounding
the appliance; for this application, please
refer to the gas installation provisions and
local regulations.

4. Instructions

Observe the following items during installation in order to
guarantee a proper and safe operation of the appliance:
• properly fi nish the edges in case of a tight construction;
• do not apply plaster on or over the fl anges;
• avoid damages when removing/placing the glass pane;
• clean the glass pane before you use the appliance, in order
to prevent dirt from burning in the glass.

5. Removing the packaging

Note the following items when removing the packaging:
!Caution
Do not allow the appliance to rest on the
lower tray (see fi g. 3)
• Check the appliance and accessories for damages during
transport.
• If necessary, contact DRU Service.
After removing the packaging, you should have the following
components:
- Allen key; you will fi nd it on top of the appliance;
- Plastic bag containing parts;
- Wood set;
- Plaster strip/decorative strip/front; upon request, the
plaster strip, decorative strip or front will be included in
the delivery.
Caution
Keep all plastic bags away from children.
In appendix 1/ table 2 you can see which parts you should
have after removing the packaging.
• Contact DRU Service if you do not have all the parts after
you fi nished removing the packaging.
• Dispose packaging in accordance with local regulations.
6. Installation
Read this manual carefully to ensure a proper and safe
operation of the appliance.
!Caution
Install the appliance in the order described
in this chapter.
6.1
Regulations
• Observe the applicable (installation) regulations.
• Observe the regulations/instructions in this manual.

6.2 Type of gas

The data plate indicates for which type of gas, gas pressure
and for which country this appliance is intended. The data
plate is attached to a chain and is placed in the air slot at
25
INSTALLATION MANUAL
Global 70XT CF