ATTENTION:
If the cause of an alarm is unclear, assume it's caused by fire. Immediately evacuate the building.
•
•
Keep the smoke detectors out of range of children.
•
Protect against dust during rennovations. Without protection the smoke detectors will lose their functi-
onality.
Maintenance:
The smoke detector is maintenance-free. In very dusty rooms they may be cleaned by vacuum.
PLAN AN ESCAPE ROUTE:
•
Make a map and mark all locations of doors and windows and a possible escape route. Note that you may need
an escape ladder on high floors.
•
Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the
escape route.
•
Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond
quickly. If you do not notice smoke or heat, check if everyone in the house is in a secure location.
•
Do not open any doors without feeling wether the door is warm or if there is smoke coming from underneath the
doors. If it is, do not open that door. If the door is cold, put your shoulder firmly against the door and open it a
small amount to check for any heat or smoke first.
•
If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire depart-
ment as soon as you are safe outside.
REPLACING THE BATTERY:
The detector is supplied using a 9Volt blok battery. Only use the recommended type GoldPeak GP1604A, GoldPeak
GP1604S, Raymax 6LR61 or EVE CR9V/P. Under normal conditions the battery will last at least one year. If it is
about to need replacement, the smoke detector will make a chirping sound every 60 seconds for at least 30 days.
Disconnect mains power before you replace the battery.
Pay attention to the polarity when replacing batteries. Test the detector after every battery replacement. If the smoke
detector does not function, please contact your supplier.
ENVIRONMENT:
Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out
as normal waste, but must be recycled as electrical waste.
TECHNICAL DATA:
Working temperature ................................................................ 0˚C tot 40˚C
Power ....................................................................................... 220-240V AC 50Hz + 9V DC Battery backup
Battery backup time
Power usage in standby ........................................................... 18 µA max.
Power usage in alert ................................................................ 45mA max.
Sound level during alert ............................................................ 85dB at a distance of 3m
Humidity .................................................................................... < 93%
Maximum link possible ............................................................. 12 SA-240 models at a maximum distance of 150M
PROBLEM
No sound during test procedure
Note: Hold the test button at least 5
seconds during the test.
The smoke alarm beeps every minute
The smoke alarm frequently gives a fal-
se alarm, constantly gives a false alarm
during cooking or when showering.
SA-240-8712412574636-Manual v2.2
If the 230V is not connected, the 9V battery will last
at least 1 year
SOLUTION
1. Remove the alarm to check if the battery is installed properly and
on the right polarity.
2. Clean the smoke alarm.
Replace the 9V battery
1. Clean the smoke alarm.
2. Move the smoke alarm to a different location.