Machine Operation
Raising/Lowering
the Floor Tool
To raise the floor-tool, ensure the floor-tool
carrier is central to the machine.
Lift the lever near the base of the handle and
lock into position.
A
!
Always ensure that chemical manufacturer's safety guidelines are followed.
!
Do not operate machine unless the Operator Manual has been read
Machine In Use
To operate, set water flow rate tap, lower the floor tool, press the vacuum / water switches, pull brush On/Off
trigger.
The waste water is then retrieved by the suction floor tool.
Overlap each scrubbing path by 10cm to ensure an even clean.
Do not operate the machine on inclines that exceed (2%), when full.
On heavily soiled floors use a 'double scrub' technique.
First pre-scrub the floor with the floor tool in the raised position, allow the
chemical time to work then scrub the area a second time with the floor
tool lowered.
If streaking occurs wipe floor tool blades clean.
Note: Care must be taken to reduce speed when cornering or when
manoeuvring around obstacles
15
www.numatic.co.uk
B
WHEN HANDLING AND MIXING CHEMICALS
Only use chemicals recommended for use in auto scrubber-dryers.
IMPORTANT
and fully understood.
Emptying Top Tank
After use, empty waste-water tank using
emptying hose and flush-out with clean water.
(fig.A).
Emptying Bottom Tank
The clean-water tank can be drained via the
yellow cap fitted to the left hand side of the
machine. There is a sealing bung beneath the
yellow cap (ensure the sealing bung is clean)
The cap should only be done up by hand.
(fig.B).
!
!