Setting the cleaning controls

A
To activate the control panel: press the
!
If the brush motor keeps overloading consider using a different type of brush.
13
www.numatic.co.uk
Mode select button or press a trigger (Fig.A).
Heavy brush load decreases the available battery run time.
To start: hold down either Trigger and press the On / Off Switch once
C
(Fig.A).
Whilst the brush motor is running press the water flow On / Off Button
for fluid control (Fig.C), the clean water On / Off tap must be open.
Ideally set the tap to 450 (Fig.B) this enables the cleaning solution to
last the same time as a fully-charged battery.
When the Triggers are released the brush motor and the cleaning
D
solution pump will switch off, the vacuum motor will continue for 10
seconds.
Press the mode select button to operate the brush only
(Fig.D).
The start sequence is required in this mode.
The water flow On / Off button will operate in this mode
Press the mode select button again to get vacuum only.
E
The On / Off Switch and triggers are not required in this mode.
(Fig.E)
Press the mode select button to switch this mode off and return to
default mode.
The panel if unused will automatically turn off after 60
seconds.
Brush Overload
The brush motor will cut out and the brush load light will flash if the
F
brush motor has been overloaded (Fig.27d).
Releasing the handle triggers will allow the machine to reset.