Maintenance
6.
Maintenance
6.1
Safety information for maintenance
D WARNING!
Hazard through a disregard of the maintenance
instructions!
This chapter contains important information for the safe
maintenance of the device.
☞ Read through this chapter carefully before carrying out
maintenance work on the device.
☞ Follow the safety instructions.
☞ Carry out the maintenance work as described.
y Repairs only by qualified specialist personnel.
D "1.2 Authorised target groups" (page 60).
y Electrical work only to be undertaken by qualified
electricians.
D "1.2 Authorised target groups" (page 60).
y Maintenance only by authorised users.
D "1.2 Authorised target groups" (page 60).
y No maintenance work permitted by children under
8 years old and persons who would not be able to
properly assess the hazards associated with handling the
device.
y After use, the hob and other parts that could be touched
may still be hot. There is a risk of burning.
y Never open the fan housing.
y The recirculated air filter must be freely accessible.
6.2
Maintenance
Replacing filter filing (with recirculated air mode)
Odours are trapped in the filter filling in the recirculated air
filter. The odour-free, cleaned room air is fed back into the
room.
Recirculated air filters are maintenance-free for up to two
years.
Then filter filling must be replaced at regular intervals.
Maintenance intervals
y Daily use: With odours in the exhaust air or after
12 months at the latest.
y Occasional use: With odours in the exhaust air or after
24 months at the latest.
80
D ATTENTION!
Danger of property damage through falling parts!
When working on the device, parts of the device or tools
could fall and damage the kitchen equipment.
☞ Protect the cooled hob and other surfaces in the cooking
area (e.g. with thick cardboard).
☞ Remove the retainer clip from the recirculated air filter.
☞ Remove the filter.
The replacement of the filter filling is carried out as
described in the associated instructions.
☞ Change the filter filling.
☞ Clean the filter from the outside (e.g. through extraction
with a vacuum cleaner).
☞ Re-fit the filter.
D "3.5.7 Install filter (with recirculated air mode)"
(page 72).
☞ Switch off the check indicator on the control panel.
D "4.4 Configuration" (page 76).
4600947_a – 05.10.2017