Installation
3.5.5
Install the hob
☞ Mount the hob.
Observe the hob instructions.
In the case of hobs with a glass thickness < 5mm:
☞ Use the additional base profiles (2x short, 2x long)
☞ Check the hob seal.
3.5.6
Connect accessories
Depending on the installation situation, accessories may be
connected to the hood:
y Wall box
y Window contact switch
y Under-pressure monitor
Observe the instructions for the accessories.
2.
Connection is implemented via cable terminals in the fan
housing. The cable terminals are labelled:
y "BMK" for the wall box connection
y "F - K" for the window contact switch or under-pressure
monitor connection
D ATTENTION!
Risk of damage through incorrect connection!
A mix-up of the control wires can result in damage to the
electronics.
☞ Be careful not to mix up connections when connecting
the control wires: Core 1 on terminal 1, core 2 on
terminal 2.
4600947_a – 05.10.2017
1.
12 V DC
H
G
12 V DC
1
2
3
BMK
F - K
D
E
B
C
A
A Control box
B Control contact
C Control contact, potential-free
D „Wall box BMK" terminal
E „Window switch F - K" terminal (multi-function contact)
F „Flap switch KS" terminal
G Control line from wall box
H Wall box
I
Wall box mains adapter
Wall box
☞ Connect the wall box as follows:
y Core 1 on terminal 1
y Core 2 on terminal 2
y The wall box is closed when the control contacts are
open.
y The wall box is open when the control contacts are
closed.
Window contact switch
☞ Connect the window contact switch as follows:
y Blue/white core to terminal 3
y Brown/green core to terminal 4
y The hood's fan is only operational when the window is
open.
Under-pressure monitor
y The hood's fan is only operational when no critical under-
pressure is determined in the room.
I