Operation
4.3.1

Run-on function

The device comes with a run-on function. If this function is
used, the device will work for a further ten minutes at the last
chosen power level.
In recirculated air mode, it is necessary to use the run-on
function so that the device can remove the remaining odours.
Using the run-on function increases the life of the filter filling.
The filter filling must be replaced at regular intervals.
The run-on function can be switched on manually or
automatically. The automatic run-on function is activated in
configuration mode.
D "4.4 Configuration" (page 76).
Touch
Function
field
The device is switched on.
If the automatic run-on function is activated:
☞ Touch the touch field 1x.
The device switches off.
The run-on time starts automatically in the last
selected power level.
If the automatic run-on function is not
activated:
☞ Touch the touch field 2x - within
2 seconds.
The device switches off.
The run-on time is started manually in the last
selected power level.
During the run-on time (10 minutes), the
operating symbol for the selected power level
will flash.
4.3.2

Check filter filling indicator

The device has a check indicator in order to remind the
operator to change the filter filling. In recirculated air mode,
the check indicator flashes every 350 hours of operation.
The hours counter is started anew by switching off the check
indicator.
The check indicator is switched off in configuration mode.
D "4.4 Configuration" (page 76).
Touch
Function
field
Touch field flashes:
The filter filling must be replaced.
D "6.2 Maintenance" (page 80).
76
4.4

Configuration

Touch
Function
field
The device is switched on, the power stages
are not active.
☞ Touch the touch field 1x - for longer than
10 seconds.
The power level touch field flashes 5x.
The device switches to configuration mode.
The configuration mode is turned on.
To exit the configuration mode:
☞ Touch the touch field 1x.
The settings are now saved.
All operating symbols illuminate for 5 seconds.
The device is in normal mode again.
In the configuration mode, the following functions can be
activated or deactivated by touching the corresponding
touch fields.
Touch
Function
field
Check filter filling indicator.
The function is set such that touch field
for recirculated air mode flashes every
350 operating hours.
The filter filling has been changed:
☞ Touch the touch field 1x.
Touch field illuminates brightly:
The hour counter starts anew, the touch field
for recirculated air mode is switched off.
Automatic run-on.
As delivered, the function is turned off.
☞ Touch the touch field 1x.
Touch field illuminates brightly:
Automatic run-on is activated.
4600947_a – 05.10.2017